Aeotec ZW175-B Manuale d'uso - Pagina 5

Sfoglia online o scarica il pdf Manuale d'uso per Interruttore Aeotec ZW175-B. Aeotec ZW175-B 8.

25.11.2019
The alarm will be triggered
1
by closed state, and be
disabled by open state.
256
Smoke alarm.
512
CO Alarm
1024
CO2 Alarm
2048
Heat Alarm
4096
Water Alarm
8192
Access Control
16384
Home Security
Value 0 and 1 cannot be used at the same time, choose one as a part of your calculation.
Use the sum of values to determine what alarms trigger your Smart Switch 7.
For example:
Value = 0 + 256 + 512 + 1024 = 1792
0 = sets the control scheme to turn on Smart Switch 7 when open alarm state happens
256 = allows Smoke Alarm signals to control SS7
512 = allows CO Alarm signals to control SS7
1024 = allows CO2 Alarm signals to control SS7
Parameter 10 - Release/Disable alarm.
Sets how you are able to disable Smart Switch 7s alarm state.
Size = 1 Byte
Default Setting = 0
Value
Description
Tap 3 times to disable the
0
alarm state.
1
Notification idle events.
Sets time in minutes on
10 - 255
how long the alarm state
should be held.
Parameter 18 - Flash frequency.
Configures the LED flash frequency and amount of time.
Size = 2 Byte
Default Setting = 0x0002 or 2
Byte
Description
Value
(MSB
Sets the flash frequency in
Value 1)
seconds. (Default = 0x0002
1 - 9
or 2)
Parameter 19 - Start/Stop LED flash (Write Only)
Sets the timeframe of flashing in seconds
Size = 2 Byte
Default Setting = 0 (disables LED flash during alarm)
Value
Description
0
Stop flashing
Set the duration in
1 - 255
seconds and start the
blinking process.
https://aeotec.freshdesk.com/support/solutions/articles/6000219911-smart-switch-7-user-guide-
Smart Switch 7 user guide : Aeotec Group
5/8