Ariston CLAS EVO SYSTEM 24 CF Manuale del prodotto - Pagina 26

Sfoglia online o scarica il pdf Manuale del prodotto per Caldaia Ariston CLAS EVO SYSTEM 24 CF. Ariston CLAS EVO SYSTEM 24 CF 48. Wall-hung gas boiler
Anche per Ariston CLAS EVO SYSTEM 24 CF: Manuale d'uso (13 pagine), Istruzioni per la manutenzione (44 pagine)

Ariston CLAS EVO SYSTEM 24 CF Manuale del prodotto
3.7
In order to improve ENERGY SAVING and COFORT are always active "Energy recovery"
e "Small tapping" functions.
3.7.1

Small tapping

Usually in standard boilers the ignition of the boiler is managed by a flow-meter that when the flow-rate
reaches a certain value (minimum flow-rate), gives the signal to the boiler to start to deliver hot water to the
user. Below this minimum flow-rate there is no DHW production, so only cold water can be supplied to the
user.
Usually the minimum flow-rate is around 1,6-2 l/min.
Tanhs to the flow-meter and 2 NTC sensors for DHW temperature control (in the tank and on the DHW flow
out of the plates exchanger), the boilers has a minimum flow rate of 0 l/min ! guaranteeing always DHW
delivery to the users.
The small tapping function has a double function :
-
also if water demand is really small from 0 l/min to 4 l/min always delivers hot water at the set
temperature
-
the electronic concept and the water stored in the tank allows to the boiler to work with an optimized
power only when the flow-rate is over 4 l/min or the tank sensor detects a temp far below the temp
set.
Pag. 26 di 48

SPECIAL FUNCTIONS