Control panel

1
2
3
4
5
Legend :
1. Green indicator CH temperarure and errors indicator
. ON/OFF button
. Green indicator ON/OFF
4. Pressure gauge
5. Winter / Summer switch - Heating temperature regulation knob
6. Domestic Hot Water adjustment knob
7. Time clock
8. Green indicator : flame ON / Red indicator : locking light
9. Yellow indicator : fumes exhaust malfunction
10. R
Initial operating procedures
If the boiler is installed inside the apartment, make
sure that all provisions relating to the air inlet
and room ventilation (in compliance with current
legislation) are respected.
Check the water pressure on the pressure gauge
regularly and make sure that the figure is between
0.6 and1.5 bar when the system is cold. If the
pressure is just under the minimum value, re-
establish the correct pressure by filling loop.
If the pressure drops very frequently, there may be a
water leak at some point in the system. If this is the
case a plumber should be contacted
Ignition procedure
Press the ON/OFF button on the control panel to
switch on the boiler.
60°
50°
40°
on/o
4
Supplied By www.heating spares.co Tel. 0161 620 6677
40°
button
eset
70°
80°
90°
1
I
60°
70°
50°
80°
90°
on/o
The green led 3 will illuminate indicating that the
boiler is ready to
operate.
The electronic control unit will ignite the burner,
without any manual intervention but in response
to the request for Domestic Hot Water or
after approximately 10 seconds, the burner has not
ignited, the boilersafety devices will shut off the gas
and the red Led 8 illuminates. To reset the ignition
system, the Reset button must be pressed and
released.
Should the boiler fail toignite a second time, check
that the external gas cock is open. If the problem
persists, contact an Authorised Service Centre.
50°
40°
1
I
heating.
60°
70°
80°
90°
on/o
1
I
10
9
8
7
6
If,