Table summarising error codes
Green Leds
Temperature indicator
40 50 60 70 80 90 yellow
●
●
●
●
●
●
●
●
●
●
●
●
●
Change of gas type
Our boilers are designed to function either with Natural Gas (methane) or L.P.G. gas. If you need
to change from one gas to the other, one of our Authorised Service Centres must be contacted to
convert the appliance.
Maintenance
Schedule an annual maintenance check-up for the boiler with a competent person.
Correct maintenance always results in savings in the cost of running the system.
Failure to arrange an annual service for the appliance will invalidate the second year of the manu-
facturers guarantee.
Supplied By www.heating spares.co Tel. 0161 620 6677
Reset
Description
red
X
Overheat
●
X
Insufficient circulation
●
Insufficient water (request filling)
C.H. Flow temp. probe circuit open / short circuit
C.H. Return temp. probe circuit open / short circuit
External sensor circuit open / short circuit
Floor Thermostat contact open
X
Heating delevery probe problem
●
Insufficient circulation
EEPROM error
Comunication error
Too many (> 5) resets in 15 minutes
X
Main P.C.B. error
●
Room sensor circuit open / short circuit
X
No flame detected
●
Flame detected with gas valve closed
X
Flame lift
●
1st Ignition Failed
nd Ignition Failed
Flame cut-off
X
Thermofuse open
●
X
Fan speed error
●
Note