Ariston ecoGENUS 24 RFFI Manuale d'uso - Pagina 17

Sfoglia online o scarica il pdf Manuale d'uso per Caldaia Ariston ecoGENUS 24 RFFI. Ariston ecoGENUS 24 RFFI 28. Condensing type c boilers
Anche per Ariston ecoGENUS 24 RFFI: Istruzioni per la manutenzione (32 pagine)

Ariston ecoGENUS 24 RFFI Manuale d'uso
D
: V
ISPLAY
IEWING
When the system is operating, i.e. while the boiler is fulfiling its normal functions,the
left-hand display will show a series of letters indicating the following functions:
- Diagnostics Stage (precedes all other functions)
0 No Request for Heat
C Heating, Burner Off
C. Heating, Burner On
c Pump Overrun for Heating
d Water for Domestic Use, Burner Off
d. Water for Domestic Use, Burner On
h Pump Overrun for Water for Domestic Use
b Storage Cylinder, Burner Off (SYSTEM version)
b. Storage Cylinder, Burner On (SYSTEM version)
276
N
F
ORMAL
UNCTIONS
LEFT
RIGHT
N
: the flashing dot on the left-hand display always indicates "burner off";
OTE
the still dot indicates "burner on".
The right-hand display (two-digit) shows:
-
in heating mode: temperature of heating system flow;
-
in domestic hot water mode: temperature domestic hot water.
S
HUTDOWN
To turn off the main burner, simply press the switch "E";
the red L.E.D. "D" will then turn off. As a precautionary
measure, it is recommended that the gas cock located
on the bottom of the boiler, is also turned off.
P
ROCEDURE
-17-