Ariston GENUS Manuale d'uso - Pagina 15

Sfoglia online o scarica il pdf Manuale d'uso per Caldaia Ariston GENUS. Ariston GENUS 17. Ariston genus boiler users manual
Anche per Ariston GENUS: Manuale d'uso (20 pagine)

Ariston GENUS Manuale d'uso
SHUTDOWN DUE TO INSUFFICIENT

WATER CIRCULATION

This anomaly is indicated by the red "D" L.E.D.
One of the possible causes of this shutdown situation
could be the lack of water in the boiler or water circula-
tion failure in the primary heating circuit.
Check the system pressure on the pressure gauge
"O" and, if it is less than 0.5 bar, consult your installer
for checking and refilling the system.
Then reset the unit by turning the boiler off and then
back on with the On/Off button "L".
If this situation persists, contact one of our Authorised
Service Centres.
B003
The "C" Summer/Winter/Flue Test selector knob can be
D
set to <
heating circuit for the purpose of analysing the fumes
produced by combustion.
To access this mode, open a water tap or taps so that the
O
flow rate is no less than 8 litres per minute.
Then press the "C" selector knob in and turn it from <
the <
>.
WARNING!
I
The flue test feature eliminates the slow-light feature.
This mode must only be selected by a qualified service engineer.
L
FLUE TEST FEATURE
(only for authorised personnel)
> to bypass temperature adjustment on the
C
> or <
> to
15