Ariston GENUS 47-116-08 Manuale di servizio - Pagina 20

Sfoglia online o scarica il pdf Manuale di servizio per Caldaia Ariston GENUS 47-116-08. Ariston GENUS 47-116-08 44. Type c

Ariston GENUS 47-116-08 Manuale di servizio
A7
A7
A8
A8
20
Supplied By www.heating spares.co Tel. 0161 620 6677
A7
A7
Fig. 1.51
Fig. 1.52

Removing the P.C.B.s

1. Isolate electricity;
2. Remove the front cover of the boiler;
3. Remove both left and right inspection panels;
4. Remove the pressure gauge cover;
5. Remove the mounting screws "A7' (see fig. 1.51) ;
6. Disconnect the connection cable"A8" (see fig. 1.52) ;
7. To remove the 24V P.C.B.: remove the electrical plug
connectors and screws "A9" (see fig. 1.53) ;
8. To remove the 240V P.C.B.: remove the electrical plug
connectors and screws "A10" (see fig. 1.54) ;
9. Replace either P.C.B. in reverse order.
A9
A9
Fig. 1.53
A10
A10
Fig. 1.54
B005