TECHNICAL AREA - reserved for qualifi ed technician
Accessing the Technical Area allows for setting/confi guring the
device according to the specifi c requirements of every installation
procedure.
It also provides important information relating to the effi cient
operation of the boiler.
The Technical Area comprises various display windows that allow
for directly accessing the parameters Intervening in each single
product installation/confi guration phase.
The parameters relating to each single menu are listed in the
following pages.
The various parameters can be accessed and modifi ed using the
button , the encoder
below).
03/02/2011
44°C
6
7
6.
ESC button (Back)
7. "encoder" programming knob
8. O
button programming key
K
For accessing the Technical Area
simultaneously press the ESC
and
buttons for 5 seconds; the
display will visualise the request for
entering the technical code.
Turn the encoder
to select 234 and press the
To move within the Technical Area turn the encoder
button to access the selected window.
Turn the encoder
to select a parameter and press
to access it.
To modify the value of a parameter, turn the encoder
button to store the value.
Use the ESC
button to exit a parameter without storing the
modifi cation and for returning to the normal viewing mode.
Technical area
Language, date and time
Complete Menu
Configuration Wizard
Service
Faults
and the ESC
button see picture
12:00
40°C
Insert code
Insert technical code
222
Save
button .
and press
and press
Example:
Modifi cation of parameter 2.3.1 Max. Adjustable Central Heating
Power
Proceed as follows:
1. Simultaneously press the ESC
the display will visualise the request for entering the technical
code.
2. Turn the encoder and select
code 234.
3. Press the
display
will
available windows.
4. Turn the encoder to select the
COMPLETE MENU.
5. Press the
the display will visualise the
available menus.
6. Turn the encoder to select Menu
2 - Boiler parameters.
7. Press the
display
will
available sub-menus.
8. Turn the encoder to select 2.3 -
Central heating 1.
9. Press the
The display will visualise the
parameters relative to sub-
menu 2.3.
8
10. Turn the encoder to select
parameter 2.3.1 - Max. C.H.
Adjustable.
11. Press the
the parameter.
The display will visualise the
value of the parameter (75%) in
addition to the minimum and
maximum values allowed.
12. Turn the encoder to select the
new value, e.g. 70%.
13. Press the
the modifi cation.
(To exit the parameter without storing the modifi cation, press the
ESC
button).
14. Press the ESC
mode.
button
and
Language, date and time
button; the
Complete MENU
Configuration Wizard
visualise
the
Service
Faults
Menù
button to access;
0
Network
1
<Not available>
2
Boiler Parameters
3
<Not available>
4
Zone1 Parameters
2 Boiler Parameters
button. The
2.0
General
visualise
the
2.1
<Not available>
2.2
General
2.3
Central Heating-1
2.4
Central Heating-2
button to access.
2.3 Central Heating-1
2.3.0
<Not available>
2.3.1
Max CH Adjustable
2.3.2
Max DHW percentage
2.3.3
min percentage
2.3.4
Max CH percentage
2.3.1 Max CH Adjustable
button to access
Maximum value
Minimum value
2.3.1 Max CH Adjustable
Maximum value
Minimum value
button to store
button to return to the normal viewing
technical area
buttons for 5 seconds;
Technical area
75
76
0
65
75 %
100%
0%
70 %
100%
0%