Ariston GENUS PREMIUM EVO HP 150 Istruzioni per la progettazione, l'installazione e la manutenzione - Pagina 39

Sfoglia online o scarica il pdf Istruzioni per la progettazione, l'installazione e la manutenzione per Caldaia Ariston GENUS PREMIUM EVO HP 150. Ariston GENUS PREMIUM EVO HP 150 44. Wall-hung condensing gas boiler hp
Anche per Ariston GENUS PREMIUM EVO HP 150: Manuale d'uso (17 pagine), Manuale d'uso (24 pagine)

Ariston GENUS PREMIUM EVO HP 150 Istruzioni per la progettazione, l'installazione e la manutenzione
Maintenance is an essential part of the safe and effi cient operation
of the boiler and ensures its durability. It should be performed
according to the instructions given in current legislation. Perform
combustion analysis regularly in order to check the operating
effi ciency of the boiler and to make sure any polluting substances
relased are within the boudaries set by current legislation.
Before beginning maintenance work:
-
Disconnect the appliance from the electricity supply by turning
the external bipolar switch to the "OFF" position;
-
Close the gas valve and the central heating and domestic hot
water system valve.
After the work has been completed the initial settings will be
restored.

General comments

It is recommended that the following inspections be carried out on
the boiler at least once a year:
1.
Check the seals in the water part and, if necessary, replace the
gaskets and restore the seal to perfect working order.
2.
Check the seals in the gas part and, if necessary, replace the
gaskets and restore the seal to perfect working order.
3.
Visually check the overall condition of the boiler.
4.
Visually check the combustion and, if necessary, disassemble
and clean the burner.
5.
Following the inspection detailed in point "3", disassemble and
clean the combustion chamber, if necessary.
6.
Following the inspection detailed in point "4", disassemble and
clean the burner and injector, if necessary.
7.
Cleaning the primary heat exchanger
8.
Make sure the following heating safety devices are operating
correctly:
- temperature limit safety device.
9.
Make sure that the following gas part safety devices are
operating correctly:
- absence of gas or fl ame safety device (ionisation).
10. Check the effi ciency of the domestic hot water production
process (test the fl ow rate and temperature).
11. Perform a general inspection of the boiler operation.
12. Remove oxide from the detection electrode using an emery
cloth.
Operational test
After having carried out the maintenance operations, fi ll the
heating circuit at a pressure of approximately 1.0 bar and release
the air from the system.
Fill the domestic hot water system at the same time.
- Begin operating the boiler.
- If necessary, release the air from the heating system again.
- Check the settings and make sure all the command, adjustment
and monitoring parts are working correctly.
- Check the seal and that the system for the expulsion of fumes/
suction of comburent air is operating correctly.
Draining procedures
The heating system must be drained using the following procedure:
- Switch off the boiler, make sure the external bipolar switch is in
the OFF position and shut off the gas valve;
- Loosen the automatic air relief valve;
- Open the system discharge valve and collect the escaping water
in a container;
- Empty the water from the lowest points of the system (where
applicable).
If the system is to be left inactive in areas where the room
temperature may fall below 0°C during winter, we recommend that
anti-freeze liquid is added to the water in the heating system in
order to avoid the need for repeated draining; when this liquid is
used make sure it is compatible with the stainless steel used for the
bodywork of the boiler.
We recommend the use of anti-freeze products which contain
PROPYLENE GLYCOLS as these inhibit corrosion and that they
are used in conjunction with the anti-scaling and anti-corrosion
function, in the quantities suggested by the manufacturer, at the
mimimum temperature.
Regularly check the pH level of the water/anti-freeze mix in the
boiler circuit and replace it when the value measured is lower than
the limit prescribed by the manufacturer.
DO NOT MIX DIFFERENT TYPES OF ANTI-FREEZE.
The manufacturer will not be held liable for any damage caused by
the appliance or the system due to the use of inappropriate anti-
freeze substances or additives.
Cleaning the primary exchanger
Cleaning the smoke side
The inside of the primary exchanger is accessed by removing the
burner. Wash with water and detergent using a non-metallic rifl e-
type brush, rinse with water.
Cleaning the siphon
The siphon is accessed by emptying the condensate bowl located
in the bottom section. Wash with water and detergent.
Replace the condensate collection bowl in its housing.
NB: in the event of prolonged use of the appliance, the siphon
must be fi lled before being used again.
A lack of water in the siphon is dangerous and may cause
smoke to be released into the atmosphere.
Draining the domestic hot water system and indirect cylinder
Every time there is a danger of freezing, the domestic hot water
system must be drained as follows:
- Shut off the water mains inlet valve;
- Open all the hot and cold water taps;
- Empty the water from the lowest points of the system (where
applicable).
WARNING
Before handling, empty all components which may contain hot
water, performing bleeding where necessary.
Descale the components in accordance with the instructions
provided on the safety data leafl et supplied with the product used,
make sure the room is well ventilated, wear protective clothing,
avoid mixing diff erent products, and protect the appliance and
surrounding objects.
Seal all openings used to take a gas pressure reading or to make
any gas adjustments.
Make sure that the nozzle is compatible with the supplied gas.
If a smell of burning is detected or smoke is seen leaking from
the appliance, or there is a smell of gas, disconnect it from the
electricity supply, shut off the gas valve, open the windows and call
for technical assistance.

Information for the user

Inform the user on how to operate the appliance.
In particular, provide the user with the instruction manuals and
inform him/her that these must be stored with the appliance.
Moreover, make sure the user is aware of the following:
- The system water pressure must be checked regularly (instruct
the user on how to fi ll and bleed the system).
- How to set the temperature and adjustment devices for using
the appliance correctly and in a more cost-effi cient way.
- The system must be serviced regularly in compliance with
legislation.
- The settings relating to the supply of combustion air and
combustion gas must not in any event be modifi ed.
maintenance
39