Remove your Door / Window Sensor 7 Pro from Z-Wave network.
Your sensor can be removed from your Z-Wave network at any time. You'll need to use your Z-Wave network's main
controller/gateway. To do this, please refer to the part of your gateway's respective manual that tells you how to remove
devices from your network.
1.
Set your Z-Wave controller into unpair mode.
2.
Triple-click the tamper switch on Door / Window Sensor 7 within 1.5 seconds.
3.
After a successful exclusion, it will green light up its LED for 2 seconds then deactivate.
Reset your Door / Windows Sensor 7 Pro.
This device also allows being reset without any involvement of a Z-Wave controller. This procedure should only be used
when the primary controller is inoperable.
To manually factory reset:
1.
Remove the cover of Door / Window Sensor 7
Press and hold tamper switch for 5 seconds until the red LED blinks.
2.
3.
Release the tamper switch
4.
Immediately press and hold the tamper switch again, a green LED will confirm reset
Association Groups.
Association groups allow Door Window Sensor 7 to directly control Z-Wave devices without the use of a Z-Wave
Controller to maximize communication efficiency.
By default, Group 1 is assigned to Node Id 01 during the pairing process of your Door / Window Sensor 7 to determine
where it should report its sensor reports to.
Group
Maximum
Number
Nodes
1
5
2
5
3
5
4
5
5
5

Parameter Configurations.

Parameter 1: Operation Mode.
9 z 14
Description
Lifeline
Control devices when a magnet or external dry contacts trips
Sends our alarm message when magnet controlled or external dry
sensor trips.
Sends alarm messages when tamper is tripped
Control devices when tilting sensor trips