Parameter 111-113 [4 byte dec] can be configured through your gateway in case the default settings of your HEM
is not what you desire.
Parameter 111 will set the interval for Group 1 (parameter 101), parameter 112 will set the interval for Group 2
(parameter 102), and parameter 113 will set the interval for Group 3 (parameter 103).
As an example, you have set parameter 101 to report the total KWH consumption and the wattage for clamp 3,
and you want to report it every 500 seconds. Set Parameter 111 [4 byte dec] to 500.
Utilizing different groups.
Your Home Energy Meter has 3 different groups that you may setup, from the settings and examples above, you may
configure each group to report different clamps and total reports to report at different interval.
Group 1 uses Parameter 101 and 111.
Group 2 uses parameter 102 and 112.
Group 3 uses parameter 103 and 113.
Technical specifications.
Model number:
DSB28-ZWUS
DSB28-ZWAU
DSB28-ZWEU
Input Voltage:
120V~, 60Hz, 20mA (USA version, 2P)
230V~, 50Hz, 10mA (EU/AU version, 1P/3P4)
380V~, 50Hz, 18mA (EU/AU version, 3P3)
Measure range of voltage:
80V~ to 150V~ (USA version, 2P)
180V~ to 260V~ (EU/AU version, 1P/3P4)
220V~ to 400V~ (EU/AU version, 3P3)
Measure range of current: 0A to 200A.
Operating distance: Up to 300 feet/100 metres outdoors.
Operating temperature: -10 to 50 .
Relative humidity: 8% to 80%.