Whirlpool AWD80AGP Manuale di servizio - Pagina 11
Sfoglia online o scarica il pdf Manuale di servizio per Lavatrice Whirlpool AWD80AGP. Whirlpool AWD80AGP 12.
E2
Heater faulty
8. Diagnostics system
No.
Fault
1
Dryer does not work
2
Drying results unsatisfactory
Lamp in the drum does not
3
work
The drying cycle end in a
very short time after the
4
program
started,
indictor is on
Drying cycle lasts long time
5
unusually
6
No heating
7
Abnormal noise
9 .Electrical circuit
Model: AWD80AGP (Galanz Model: DV-70Q1K)
Harness disconnect
Heater faulty
PCB faulty
Harness disconnect
Wire faulty
Possible cause
·Mains plug is not plugged in
·door is open
·Wrong program selected
·Filter clogged
·Incorrect volume of laundry
·Sediment in the humidity
sensor
·Lamp is defective
The load is not enough or the
clothes is already dry enough
"End"
for the selected program
The load volume is excessive
for the capacity of the dryer
·The thermostat is out of
connection
unnormal operation
·The heater is faulty
·The thermostat is faulty
·The wire is faulty
·The pcb is faulty
·The dryer is not level on the
ground
·The voltage is not 220-230V
·The motor faulty
·The micro-v belt faulty
Connect the harness
Change heater
Change PCB
Connect the harness
Change wire
·Plug in main socket
·Close door
·Choose proper program
·Clean filter
·Comply recommended loading
volumes
·Clean the humidity sensor surface
·Replace lamp
·Choose a program with higher
drying level. e .g choose heavy
strong program
Reduce the clothes
·Press the reset button
because
of
·Replace the heater
·replace the thermostat
·Replace the wire
·Replace the pcb
·Adjust the adjustable foot
·Connect the right voltage
·Replace the motor
·Replace the micro-v belt
10
Solution