QUICK OVERVIEW TEST MODE (Page 8)
To access Quick Overview Test Mode, perform steps 1 and 2 of
Activating the Service Diagnostic Test Modes. Toggle the cycle
selector knob until the status LEDs correspond as follows:
 "Final Spin" LED On
In
Soak/
Use
Wash
NOTE: Status LED names may vary between makes and models.
Press the START button to begin the Quick Overview test. See
page 8 for order of Quick Overview test.
U pon entering the Quick Overview test mode, the washer will
perform an automatic test with water cycles to check major
washer functions.
P ressing the START button will manually advance to the
next step.
P ress and hold the START button for 3 seconds at any time
to exit any test mode.
IMPORTANT: Lid must be closed with lid lock enabled
to perform test.
MANUAL OVERVIEW TEST MODE (Page 9)
To access Manual Overview Test Mode, perform steps 1 and 2
of Activating the Service Diagnostic Test Modes. Toggle the cycle
selector knob until the status LEDs correspond as follows:
 "Final Spin & Done" LEDs On
In
Soak/
Use
Wash
Press the START button to enter Manual Overview Test Mode.
See page 9 for Manual Overview Test Mode.
U pon entering the Manual Overview test mode, the washer
will have all outputs OFF.
T he cycle selector knob is used to select the output
to be tested.
T he START button will activate/deactivate the selected output.
W hen the selected output is activated, the corresponding
status LEDs flash ON & OFF.
P ress and hold the START button for 3 seconds at any time
to exit any test mode.
IMPORTANT: As a safety feature, the lid must be closed
with lid lock enabled to activate either Agitate or Spin Test.
NOTE: Multiple outputs may be activated simultaneously.
NOTE: Outputs left on will time-out after 5 minutes.
CALIBRATION MODE
IMPORTANT: Calibration must be performed when any of
the following components have been replaced: Main Control,
Basket, Drive Assembly, Suspension, Motor, and Capacitor.
Calibration should also be performed when the washer is moved
to a different location or, more specifically, to a different power
outlet. Not performing calibration may result in poor wash
performance.
To access Calibration Mode, perform steps 1 and 2 of Activating
the Service Diagnostic Test Modes. Toggle the cycle selector
knob until the status LEDs correspond as follows:
 "Rinse" LED On
In
Soak/
Use
Wash
PAGE 4
FOR SERVICE TECHNICIAN'S USE ONLY
Final
Rinse
Spin
Done
Final
Rinse
Spin
Done
Final
Rinse
Spin
Done
NOTE: Status LED names may vary between makes and models.
Press the START button to begin washer calibration. All status
LEDs will turn on.
D o NOT interrupt calibration, disturb washer, or remove
power; otherwise, calibration must be repeated.
L id must be down to perform test.
B asket must be empty to perform test (no water or clothes).
C alibration cycle runs for approximately 2–4 minutes.
Cycle completes when door unlocks and washer enters
standby mode.
DRAIN & SPIN CYCLE
To access the Drain & Spin Cycle, perform steps 1 and 2
of Activating the Service Diagnostic Test Modes. Toggle the cycle
selector knob until the status LEDs correspond as follows:
 "Rinse & Done" LEDs On
In
Soak/
Use
Wash
Press the START button to start the Drain & Spin Cycle.
UI TEST MODE
To access UI (User Interface) Test Mode, perform steps 1 and 2
of Activating the Service Diagnostic Test Modes. Toggle the cycle
selector knob until the status LEDs correspond as follows:
 "Rinse & Final Spin" LEDs On
(1)In
(2)Soak/
Use
Wash
NOTE: Status LED names may vary between makes and
models. Use LED # identifications.
Press the START button to begin the UI test.
U pon entering the UI test mode, all status LEDs will be
turned ON.
P ressing the START button will turn on and off all status
LEDs, or toggle the state of each status LED independently.
(Example: if 2 are on, and 3 are off, then 2 will be turned off
and 3 turned on.)
W hen toggling the cycle selector knob, each double click
will toggle the "Done" (5) LED.
T urning the rotary switch will toggle the following status LED
on and off.
• (1) In Use LED
P ress and hold the START button for 3 seconds.
W asher will exit UI test mode after 5 minutes of inactivity
or unplugging the power cord.
Final
Rinse
Spin
Done
(4)Final
(3)Rinse
Spin
(5)Done
DO NOT REMOVE OR DESTROY