Whirlpool 2199011 Manuale d'uso e manutenzione del frigorifero - Pagina 7
Sfoglia online o scarica il pdf Manuale d'uso e manutenzione del frigorifero per Frigorifero Whirlpool 2199011. Whirlpool 2199011 43. Whirlpool top-mount refrigerator use&careguide 2199011
3. Find a
-inch to 1 -inch vertical COLD water pipe
near the refrigerator.
NOTE: Horizontal pipe will work, but the following
precaution must be taken: Drill on the top side of the
pipe, not the bottom. This will help keep water away
from the drill. This also keeps normal sediment from
collecting in the valve.
4. To determine the length of copper tubing you will need,
measure from connection on lower left rear of
refrigerator to water pipe. Add 7 feet (2.1 m) to allow for
moving refrigerator for cleaning. Use
(outside diameter) copper tubing. Be sure both ends of
copper tubing are cut square.
5. Using a grounded drill, drill a
water pipe you have selected.
1. Cold Water Pipe
2. Pipe Clamp
3. Copper Tubing
4. Compression Nut
5. Compression Sleeve
6. Shut Off Valve
7. Packing Nut
6. Fasten shut-off valve to cold water pipe with pipe
clamp. Be sure outlet end is solidly in the
hole in the water pipe and that washer is under the pipe
clamp. Tighten packing nut. Tighten the pipe clamp
screws carefully and evenly so washer makes a
watertight seal. Do not overtighten or you may crush
the copper tubing, especially if soft (coiled) copper
tubing is used. Now you are ready to connect the
copper tubing.
7. Slip compression sleeve and compression nut on
copper tubing as shown. Insert end of tubing into outlet
end squarely as far as it will go. Screw compression nut
onto outlet end with adjustable wrench. Do not
overtighten.
8. Place the free end of the tubing into a container or sink,
and turn ON main water supply and flush out tubing
until water is clear. Turn OFF shut-off valve on the water
pipe. Coil copper tubing.
-inch O.D.
-inch hole in the cold
-inch drilled
Connecting to refrigerator:
1. Attach the copper tube to the valve inlet using a
compression nut and sleeve as shown. Tighten the
compression nut. Do not overtighten. Use the tube
clamp on the back of the refrigerator to secure the
tubing to the refrigerator as shown. This will help
prevent damage to the tubing when the refrigerator is
pushed back against the wall. Move to step 2.
2. Turn shut-off valve ON. Check For Leaks. Tighten
any connections (including connections at the valve) or
nuts that leak.
1. Tube Clamp
2. Copper tubing
3. Compression Nut
4. Valve Inlet
3. The ice maker is equipped with a built-in water strainer.
If local water conditions require periodic cleaning or a
well is your source of water supply, a second water
strainer should be installed in the
Obtain a water strainer from your nearest appliance
dealer. Install at either tube connection.
4. Plug in refrigerator or reconnect power.
-inch water line.
7