Section one: Deactivating ADc2000 control Routine

ADc 2000
Figure 1
1)
Locate resistor number 10 (R10) on top side of circuit board (figure. 1)
2)
Using wire cutters clip both legs (wire) of the resistor as close
to the board surface as possible.
3)
With resistor removed, no leg (wire) of the resistor should be able to
make contact with any other component. The legs (wire) should be
removed as close to the circuit board as possible (figure. 1A)
4)
The ADC routine is now deactivated.
5)
Reinstall all components and wiring harnesses
6)
Replace all parts and panels
7)
Plug in refrigerator or reconnect power.
location of R10
ADc 2000
R10 Removed
Figure 1A