Sfoglia online o scarica il pdf Manuale d'installazione e d'uso per Unità di controllo ABB Baldor BC142-5. ABB Baldor BC142-5 20. Dc control

ABB Baldor BC142-5 Manuale d'installazione e d'uso
AC Line
Catalog
VAC
Number
(±15%,
50/60Hz)
BC141
115
BC142
230
115
BC142-5
230
115
BC142-6
230
Description
Speed Range (Ratio)
Armature Feedback Load Regulation (0 - Full Load, 50:1 Speed Range) (%
Base Speed)
Tachometer Feedback Load Regulation (0 - Full Load, 50:1 Speed Range) (%
Set Speed)
Line Voltage Regulation (at Full Load, ± 10% Line Variation) (% Speed)
Control Linearity (% Speed vs. Dial Rotation)
Acceleration (ACCEL) Trimpot Range (Seconds)
Deceleration (DECEL) Trimpot Range (Seconds)
Maximum Speed (MAX) Trimpot Range (% Base Speed)
Minimum Speed (MIN) Trimpot Range (% Base Speed)
Current Limit (CL) Trimpot Range (% Full Load)
IR Compensation (IR) Trimpot Range (at Specified Full Load @ 90, 180 Volts DC
Output) (Volts DC)
Maximum Operating Ambient Temperature at Full Load - °C / °F
MN704
Table 1-1 Electrical Ratings
Rating without Auxiliary Heat
Sink
Motor
Max DC
Max
VDC
Load
AC Line
Current
Current
Amps
Amps
0-90
12
8
0-180
12
8
0-90*
12
8
0-90
9
6
0-180
9
6
0-90*
9
6
0-90
12
8
0-180
12
8
0-90*
12
8
Table 1-2 General Performance Specifications
Rating with Auxiliary Heat Sink
Max DC
Max
Max
Load
AC Line
Power
Current
Current
HP (kW)
Amps
Amps
.75 (.6)
24
16
1.5 (1.1)
24
16
.75 (.6)
24
16
.75 (.6)
18
12
1.5 (1.1)
18
12
.75 (.6)
18
12
.75 (.6)
24
16
1.5 (1.1)
24
16
.75 (.6)
24
16
Specification
50:1
1
1
0.5
2
0.2 – 10
0.2 – 10
50 – 110
0 – 30
0 – 200
0 – 24, 48
40 / 104
Field
VDC
(1.13
Max
Power
Amps
HP (kW)
Max)
1.5 (1.1)
50, 100
3 (2.3)
100, 200
1.5 (1.1)
100
1.5 (1.1)
50, 100
3 (2.3)
100, 200
1.5 (1.1)
100
1.5 (1.1)
50, 100
3 (2.3)
100, 200
1.5 (1.1)
100
Factory
Setting
2
2
100
0
150
3, 6
1-3