Whirlpool  LER3622PQ Dimensioni

Sfoglia online o scarica il pdf Dimensioni per Asciugatrice Whirlpool  LER3622PQ. Whirlpool  LER3622PQ 1. Cabrioâ® high efficiency electric dryer with accudryâ„¢ drying system ventilation specification
Anche per Whirlpool  LER3622PQ: Manuale d'uso e manutenzione (20 pagine), Manuale d'uso e manutenzione (20 pagine), Manuale di istruzioni (8 pagine)

Whirlpool  LER3622PQ Dimensioni
®
Electric Compact Dryer
PRODUCT MODEL NUMBERS
LER3622P
Electrical: A four-wire or three-wire, single
phase, 120/240-volt, 60-Hz, AC-only, electrical
supply (or 120/208-volt electrical supply, if
specified on the serial/rating plate) is required on a
separate 30-amp circuit, fused on both sides of the
line. A time-delay fuse or circuit breaker is
recommended.
Exhaust venting: Exhaust your dryer to the
outside. Four-inch diameter vent is required. Rigid
or flexible metal exhaust vent must be used. Do
Not use plastic or metal foil vent. Exhaust outlet
hood must be at least 12 inches from the ground
or any object that may be in the path of the
exhaust.
RECESSED AREA AND CLOSET INSTALLATION
Recessed or closet installation - Dryer only
14"
(35.6cm)
18" (45.7 cm)
3"
0"*
(7.6 cm)
(0 cm)
A
A. Side view - closet or confined area
B. Recessed area
*Additional spacing recommended
EXHAUST VENTING
Recommended hood styles
B
A
4"
(10.2 cm)
4"
(10.2 cm)
A. Louvered hood style
B. Box hood style
Select the route that will provide the straightest and most direct path
outdoors. Plan the installation to use the fewest number of elbows and turns.
Use the fewest 90° turns possible.
Do not use vent runs longer than specified in vent length chart.
Determine the number of elbows you will need.
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
OVERALL DIMENSIONS
*Most installations require a
minimum 5 " (14.0 cm)
clearance behind the dryer for
the exhaust vent with elbows.
Recessed or closet installation - Stacked
12"
(30.5 cm)
12"
(30.5 cm)
0"*
0"*
(0cm)
(0 cm)
B
Angled hood style
is acceptable.
4"
(10.2 cm)
2.5"
(6.4 cm)
3"
(7.6 cm)
DRYER
WASHER
0"*
1"
(0 cm)
(2.5 cm)
A
B
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
Vent system chart
Number of
Type of
90º turns
vent
or elbows
0
Rigid metal
Flexible metal
1
Rigid metal
Flexible metal
2
Rigid metal
Flexible metal
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
3
20
"
*
4
(52.7 cm)
31"
(78.7 cm)
7
23
"
8
(60.6 cm)
Closet confined area
For closet installation
3"
with a door, minimum
(7.6 cm)
ventilation openings
2
48 in.
in the top and bottom
2
(309.7 cm )
of the door are
required. Louvered
doors with equivalent
ventilation openings
are acceptable.
2
24 in.
2
(154.8 cm )
3"
(7.6 cm)
C
Box or
Angled
louvered
hoods
hoods
36 ft (11 m)
26 ft (7.9 m)
28 ft (8.5 m)
22 ft (6.7 m)
26 ft (7.9 m)
16 ft (4.9 m)
18 ft (5.5 m)
12 ft (3.7 m)
16 ft (4.9 m)
6 ft (1.8 m)
8 ft (2.8 m)
2 ft (0.6 m)
Ref. 8577196