Fireplace K1266 Manuale - Pagina 14

Sfoglia online o scarica il pdf Manuale per Stufa Fireplace K1266. Fireplace K1266 19.

‚ ' ( ' ( ) ' 0 1 2 3 1 1 2 ' 4 1 5 6 ' 2 ' 3 1 4 7 8 9 7 0 @ A B 7 4 ' C D ' ' 8 E 2 @ F 9 0 ' A 3 A 9 9 @ 4 3 ) F ' 9 8 ' 5 G
ple away from the appliance while operating.
Maintain the settings of the air that is necessary for the burning capacity of the
stove and keep in mind that the settings of the air depend considerably on the
actual chimney draught. Set the amount of air according to your experience.
Bad air settings can lead to blackening of the glass front or damage to the appli-
ance, the connecting pipe and the chimney.
The lining of the combustion chamber (chamotte or vermiculite) can turn black
when you light the fire. This blackening disappears when the stove reaches its
operating temperature.
Always empty the ash drawer before each use, while the unit and the ashes are
cold, because a full ash drawer can
-
obstruct air supply
-
damage the grate
After emptying the ash drawer, replace it immediately.
Always store the ash in a fire-proof container. Do not put the container close to
combustible materials or place it on a combustible surface. Use a protective
plate if necessary. Pour the ash into a waste receptacle only after you make
sure that it has completely cooled down.
The condition of proper operation of the fireplace is the appropriate chimney
draught (feed pressure). This is considerably dependent on the temperature of
the outer environment. In case of a higher outer temperature (above 15°C) feed
pressure can considerably fall and it can disturb proper operation. Do not use
the appliance in such cases.
Attention!
Combustible remains are deposited in the appliance, the connecting pipe and
the chimney during use. This happens increasingly if you use wet or treated
wood or fuel that is not allowed. The possible overload of the stove or restrain
of the fire can contribute to this also. It is rare that the deposits catch fire due
to the lack of regular cleaning. However, this can be noticed from the black
smoke flowing out of the chimney, the rise of the temperature of the chimney
wall and the increased draught that can result in a whistling sound.
In case of such a fire in the chimney, call the fire-fighters and close all air
regulators and outlets. Inform the chimney sweep. Do not spray or pour
water in the chimney in any case because it can lead to gas explosion.
Remove all combustible, heat sensitive materials from the environment of