Whirlpool 3405338 Manuale di istruzioni per l'installazione - Pagina 2

Sfoglia online o scarica il pdf Manuale di istruzioni per l'installazione per Asciugatrice Whirlpool 3405338. Whirlpool 3405338 10. Gas dryer part no. 3405338

Whirlpool 3405338 Manuale di istruzioni per l'installazione
Dryer location
and dimensions
14-1/2"
42-3/8"*
6"*
9-1/4"
2-1/8"
gas burner inlet
pipe connection
at rear of dryer
28" max.**
*from floor with
dryer feet
extended 1 inch
For proper drying performance:
The location must provide:
Protection from weather and water: Do not
store or use dryer where it will be exposed to
water and weather.
Room temperature above 45°F: If room
temperature is below 45°F, automatic cycles
may not shut off.
It is your responsibility to:
Observe all governing
codes and ordinances.
Check code requirements:
Some codes limit or do not
permit installation of clothes
dryers in garages, closets,
mobile homes or sleeping
quarters. Contact your local
building inspector.
Recessed area/closet installation
Installation clearances.
Use recommended clearance for easier
installation.
Recommended/Minimum
Recessed
Back
Sides
5"/0"
1"/0"
Exhausted
18"/18"
5"/4"
1"/0"
Closet
18"/18"
No other fuel burning appliance may be
installed in the same closet or recessed area.
• If codes permit, dryer may be installed in a
recessed area or closet using dimensions
shown.
• Dimensions are in inches and are the
minimum allowable. Detailed space
requirements can also be found on the label
on the back panel of the dryer. These
requirements ensure minimum clearances to
combustible construction, and prevent
blockage of air into the combustion chamber.
• Additional spacing should be considered for
ease of installation and servicing. Companion
appliance spacing should also be considered.
Door clearance
Location must be large enough to fully open dryer door.
3-7/8"
22-3/4"
19-1/8"
Super-large
side-swing door (reversible)
Panel A
WARNING: For your safety the
information in this manual must
be followed to minimize the
risk of fire or explosion or to
prevent property damage,
personal injury or death.
— Do not store or use gasoline,
— WHAT TO DO IF YOU SMELL
dryer exhaust
vent
• Do not try to light any
29"
**Most installations will
require at least 5-inch
clearance behind the
dryer for the dryer vent.
Level floor: Maximum slope under entire dryer
should not be more than 1 inch. (If slope is
greater than 1 inch, install Extended Dryer Feet
Kit, Part No. 279810.) Clothes may not tumble
properly and automatic sensor cycles may not
operate correctly if dryer is not level.
Comply with the installation
specifications and
dimensions.
Consider spacing
requirements for companion
appliances.
Make sure you have
everything necessary for
proper installation.
Recessed area installation
Top
Front
1"/1"
0"******
******
Wall, door and floor molding may require
additional spacing.
22-3/4"
22-3/4"
Large side-swing
door (reversible)
or other flammable vapors and
liquids in the vicinity of this or
any other appliance.
GAS:
appliance.
Keep flammable materials and vapors, such as gasoline, away from dryer.
Place dryer at least 18 inches above the floor for a garage installation.
Failure to do so can result in death, explosion, or fire.
Properly install dryer.
Contact a qualified installer
to insure that the electrical
and gas installations meet all
national and local codes and
ordinances.
Exhaust to outdoors: Dryer
must be exhausted outdoors
to prevent exposure to
harmful substances in the gas
fuels.
front view
18"
0"******
7"
15-1/4"
17-3/4"
22-3/4"
Small side-swing door
• Do not touch any electrical
switch; do not use any phone
in your building.
• Clear the room, building or
area of all occupants.
• Immediately call your gas,
supplier from a neighbor's
phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas
supplier, call the fire
department.
— Installation and service must
be done by a qualified
installer, service agency or
the gas supplier.
WARNING
Explosion Hazard
Sturdy floor to support dryer weight of
175 pounds.
This installation must also conform with the
American National Standard, National Fuel
Gas Code ANSI Z223.1 — latest edition***,
and all local codes and ordinances.
Copies of the standards listed may be obtained
from:
***American Gas Association
1515 Wilson Boulevard
Arlington, Virginia 22209
Closet/confined area installation
If a closet door is installed: The minimum
unobstructed air openings are required.
Louvered doors with equivalent air openings
are acceptable.
front view
3"
****
48 sq. in.
closet
door
****
24 sq. in.
3"
****
Minimum top and bottom air openings for
closet door.
*****
External exhaust elbow requires additional
space.
25-5/8"
8-1/4"
15-1/4"
13-3/4"
15-1/4"
Extra-large hamper door
side view
14"
max.
*****
4"
1"
8-3/4"
13-3/4"