Electrical
requirements
If codes
permit
and a separate
ground
wire is used, it is
recommended
that a qualified
electrician
determine
that the ground
path is adequate.
Important:
Observe
all governing
codes and ordinances.
A four-wire
or three-wire,
single-phase,
120/240-volt,
60-Hz, AC-only
electrical
supply (or four-wire
or three-wire,
120/208-volt,
if specified
on the
model/serial
rating plate)
is required
on a separate,
30-ampere
circuit,
fused on both sides of the line. A
time-delay
fuse or circuit
breaker
is
recommended.
The model/serial
rating plate
is located
in the door
well behind
the dryer door on the
front of the opening.
A wiring diagram
is located
inside the
console
or on back panel
of dryer.
It is the personal
responsibility
and
obligation
of the customer
to contact
a qualified
electrician
to assure that
the electrical
installation
is adequate
and in conformance
with the
National
Electrical
Code, ANSI/NFPA
70 -
latest edition*,
and all local
codes
and ordinances.
Copies of the standards listed above may
be obtained from:
l
National Fire Protection Association
Batterymarch
Park
Quincy, Massachusetts 02269
Power supply cord
Use a new 30-amp
power supply
cord.
Local codes
may permit
the use of a
U.L.-listed, 120/240-volt
minimum,
30-
ampere,
dryer power
supply cord kit
(pigtail).
Power supply cord should be
Type SRD or SRDT and be at least four
feet long. The wires that connect
to
the dryer must end with ring terminals
or spade
terminals
with upturned
ends.
A 3/4", U.L.-listed strain relief must be
installed
where
the power
supply cord
connects
to the dryer (see Figures 2
and 3).
spade
----
terminals with
upturned ends
strain relief \
(whtte)
P
NEUTRAL
grbund prong
Four-wire
power
supply
cord
NEMA 14-30P
Figure
2
-
9l
&!i%zq$
This blade connected
terminal
NEUTRAL /to
this conductor.\
(white or cente
Three-wire
power supply
cord
NEMA lo-30P
Figure
3
For use where
local codes
permit use of
flexible power
supply cord.
four-wire
receptacle
(14- JOR)
Figure
4
three-wire
receptacle
(1 O-30R)
Figure
5
Four-wire
installation
is
recommended:
The power supply
cord must have four, No.-1 0 copper
wires and match
a four-wire
receptacle
of NEMA Type 14-30R (see
Figure 4). The fourth wire (ground
conductor)
must be identified
with a
green
cover and the neutral
conductor
by a white cover.
Three-wire
installatton
(it a four-wire
system is not available):
The power
supply cord must have three, No.-1 0
copper
wires to match
a three-wire
receptacle
of NEMA Type 1 O-30R (see
Figure 5).
Direct wire
The dryer can be connected
directly
to fused disconnect
or circuit breaker
box with four-wire
or three-wire
flexible
armored
or non-metallic
sheathed
copper
cable
(with ground
wire). Do Not use two-wire
with bare
ground
wire. All current-carrying
wires
must be insulated.
A U.L.-listed conduit
connector
must
be installed
at the junction
box. USE
ONLY lo-GAUGE
SOLID COPPER WIRE.
DO NOT USE ALUMINUM
WIRE. Allow
four feet of slack in the line so dryer
can be moved
if servicing
is ever
necessary.