Whirlpool 3406449 Manuale di istruzioni per l'installazione - Pagina 9

Sfoglia online o scarica il pdf Manuale di istruzioni per l'installazione per Asciugatrice Whirlpool 3406449. Whirlpool 3406449 12. Commercial 27" electronic dryer

Electrical
Shock Hazard
Turn power supply
off before
connecting
wires.
Use 10 gauge solid copper wire.
Electrically
ground
dryer.
Failure to follow
these
instructions
can result in death,
fire, or electrical
shock.
1
. Turn power supply
off.
2
. Strip 3-l /2 inches of outer
covering
from end of cable.
If using
three-wire
cable
with ground wire,
cut the bare wire even with outer
covering.
Strip 1 inch of insulation
from the end of each insulated wire
(see Figure 17).
Bare wire cut short. Mire is not
used. Dryer is grounded
through dire:t wire cable.
314"
U.L.-listed
wire stripped
of insulation
@omex)
I
Direct wire preparation
Figure 17
Shape the end of
each
wire into a
u
'U" shaped
hook
~~~~ped
(see Figure 18).
Figure
18
3~
. Remove holddown
screw and
terminal block cover.
-
Figure 19 u
4
. Attach
314" UL-
rear
listed strain relief
(U.L. marking
on
strain relief) to the
hole below
terminal
box opening
(see
Figure 20). Tighten
strain relief firmly to
cabinet
so it is in a
horizontal
position.
strain relief
Place direct wire
(outside dryer)
cable
through
strain
Figure 20
relief.
5
. Loosen or remove
terminal
block screws.
Connect
the neutral
wire (white or center)
of direct wire
cable
under the center
screw of
the terminal
block. Place the hook-
shaped
end of the wire over the
terminal
block screw with open side
of the hook facing
to the right.
Squeeze
hook end of wire together
to form a loop.
Connect
the other two wires under
the outer terminal
block screws.
Attach
wires using the same
method
as the neutral wire (see
Figure 21).
Tighten
all terminal
block screws
firmly.
Center
wire MUST be connected
to
center
screw.
green with
external ground
yellow
connector
stripes
(attached
at factory)
/-
center
screw
(neutral)
red
strain
'relief
center lea
must be
connected
to center
screw
strain
relief
screws
screws
-..--.
wire
cable
Figure 21
6
. Tighten
strain relief screws.
7
. Insert tab of terminal
block
cover into slot of the dryer rear
panel
(See Figure 19). Secure
cover with hold-down
screw.
Power Supply Cord
or Direct Wire
Where local codes DO NOT
permit connecting
the frame-
ground
conductor
to the
neutral (white) wire:
1
a.
Turn power supply
off.
2a.
Complete
Power Supply Cord
Steps 2-3, Page 7 or Direct Wire Steps
2-4, Pages 7-8.
neutral ground
external ground
connector
\
wire
-
(green/yello~-
w
striped . ...__\
3;.
/
WlW,
must be
-connected
center screw
(neutral)
to center
screw
Figure 22
&I.
Remove
the neutral
ground
wire
(green/yellow
striped
wire) from
external
ground
connector
screw.
Remove
center
terminal
block screw
and fasten neutral
ground
wire to
screw (see Figure 22).
&I.
Complete
Power Supply Cord
Steps 4-6, Page 7, or Direct Wire Steps
5-7, Page 8.
5a.
After reattaching
the terminal
block cover, connect
separate
copper
ground
wire from external
ground
connector
to grounded
metal
cold water
pipe.
Contact
a
qualified
electrician
to assure that
ground
path is adequate
(see Figure
23).
terminal
I
block cover
separate copper ground
wire connected
and
grounded to a grounded,
metal, cold water pipe
Figure 23
Page 9