Power Supply Cord Connection

Power supply cord strain relief
1.
Attach power supply cord strain relief
Remove the screws from a 3/4" (19 mm) UL listed strain relief
(UL marking on strain relief). Put the tabs of the two clamp
sections (C) into the hole (B) below the terminal block opening
so that one tab is pointing up (A) and the other is pointing
down (D), and hold in place. Tighten strain relief screws just
enough to hold the two clamp sections (C) together.
2.
Attach power supply cord strain relief
Put power supply cord through the strain relief. Be sure that
the wire insulation on the power supply cord is inside the
strain relief. The strain relief should have a tight fit with the
dryer cabinet and be in a horizontal position. Do not further
tighten strain relief screws at this point.
For 3-wire Power Supply Cord Connection, see page 31.
For 4-wire Power Supply Cord Connection, continue to
step 3.
32

4-Wire Power Supply Cord Connection

IMPORTANT: A 4-wire connection is required for mobile
homes and where local codes do not permit the use of 3-wire
connections.
A
A
B
C
D
3.
Prepare to connect neutral ground
wire and neutral wire
Remove center terminal block screw (B). Remove neutral
ground wire (E) from external ground conductor screw (A).
4.
Connect neutral ground wire and
neutral wire
E
Connect neutral ground wire (E) and neutral wire (white or
center) (C) of power supply cord under center terminal block
screw (B). Tighten screw.
B
C
D
E
A. 4-wire receptacle (NEMA type 14-30R)
B. 4-prong plug
C. Ground prong
D. Neutral prong
E. Spade terminals with upturned ends
F. 3/4" (19 mm) UL listed strain relief
G. Ring terminals
E
C
F
G
A
B
B