Whirlpool DryAire LMA1053LQ Manuale - Pagina 27

Sfoglia online o scarica il pdf Manuale per Asciugatrice Whirlpool DryAire LMA1053LQ. Whirlpool DryAire LMA1053LQ 32. Drying cabinet

Whirlpool DryAire LMA1053LQ Manuale
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.

TIMER

b0 / b1
Terminals
B Terminal
Refer to page 4-4 for the procedure for servic-
ing the timer.
1.
Disconnect the power to the drying cabi-
net.
2.
Disconnect the wires from the A and a0/a1
terminals, and the B and b0/b1 terminals.
3.
Turn the timer to 0 (off).
4.
Set the ohmmeter to the R x 1 scale.
5.
Touch the ohmmeter leads to the A and
a0/a1 terminals. The meter should indi-
cate an open (infinite) circuit.
6.
Touch the ohmmeter leads to the B and
b0/b1 terminals. The meter should indi-
cate an open (infinite) circuit.
7.
Turn the timer to the 1 (On) position.
8.
Repeat steps 5 and 6. The meter should
indicate a closed circuit (0 Ω) in both steps.
Electrical Shock Hazard
a0 / a1
Terminals
A Terminal
WARNING
DOOR & PUSH-TO-START (PTS)
SWITCHES
Door Switch
Refer to page 4-7 for the procedure for servic-
ing the door and push-to-start switches.
1.
Disconnect the power to the drying cabi-
net.
2.
Disconnect one of the wires from the door
switch or the push-to-start switch termi-
nals.
3.
Set the ohmmeter to the R x 1 scale.
4.
Touch the ohmmeter leads to the switch
terminals. The meter should indicate an
open (infinite) circuit.
5.
Press the switch actuator.
6.
Touch the ohmmeter leads to the switch
terminals. The meter should indicate a
closed circuit (0 Ω).
5-3
PTS Switch