Whirlpool WGD97HEXL0 Manuale di istruzioni per l'installazione - Pagina 11

Sfoglia online o scarica il pdf Manuale di istruzioni per l'installazione per Asciugatrice Whirlpool WGD97HEXL0. Whirlpool WGD97HEXL0 38. Gas dryer

Whirlpool WGD97HEXL0 Manuale di istruzioni per l'installazione
P an
Vent
System
Choose
your exhaust
installation
type
Recommended
exhaust
installation:
.......
O
........
Standard rear exhaust installation
Optional
exhaust installations:
Fire Hazard
Cover unused exhaust holes with a manufacturer's
exhaust cover kit.
Contact your local dealer.
Failure to follow
these instructions can result in death,
fire, electrical shock, or serious injury,
Exhaust can be converted out the right side, left side, or through
the bottom (4-way vent kit, part number W10337804).
Each kit
includes step-by-step
instructions.
Special
provisions
for mobile
homes:
Exhaust vent must be securely fastened to a noncombustible
portion of mobile home and must not terminate beneath the
mobile home. Terminate exhaust vent outside.
!
Bottom exhaust installation
Determine
vent path:
[] Select route that will provide straightest and most direct
path outdoors.
[] Plan installation to use fewest number of elbows and turns.
[] When using elbows or making turns, allow as much room
as possible.
[] Bend vent gradually to avoid kinking.
[] Use as few 90 ° turns as possible.
Determine
vent length and elbows
needed
for best
drying
performance:
[] Use following Vent system chart to determine type of vent
material and hood combinations
acceptable to use.
NOTE: Do not use vent runs longer than those specified
in Vent system chart.
Exhaust systems longer than those specified will:
[] Shorten life of dryer.
[] Reduce performance,
resulting in longer drying times
and increased energy usage.
The Vent system chart provides venting requirements that will
help achieve best drying performance.
NOTE: Side and bottom exhaust installation have a 90 ° turn
inside the dryer. To determine maximum exhaust length, add
a 90 ° turn to the total number of elbows when referemcing
the chart.
Vent system
chart
Number of
90° elbows
0
1
2
3
4
Type
of vent
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Box/Iouvered
hoods
64 ft. (20 m)
54 ft. (16.5 m)
44 ft. (13.4 m)
35 ft. (10.7 m)
27 ft. (8.2 m)
Angled
hoods
58 ft. (17.7 m)
48 ft. (14.6 m)
38 ft. (11.6 m)
29 ft. (8.8 m)
21 ft. (6.4 m)