Whirlpool XCGM2765 Manuale di istruzioni per l'installazione - Pagina 12
Sfoglia online o scarica il pdf Manuale di istruzioni per l'installazione per Asciugatrice Whirlpool XCGM2765. Whirlpool XCGM2765 23. Commercial gas or electric dryer
ELECTRIC DRYER INSTALLATION REQUIREMENTS
Electrical Requirements
This dryer is supplied without an electric cord and plug. It
must be connected by a Whirlpool authorized service person
to a single-phase electricity supply at the voltage shown
on the dataplate, using a suitable fixed wiring installation in
accordance with local and national wiring regulations.
■ A 3-wire circular cord of minimum conductor size 2.5 mm
cross-section area should be used.
■ A 25A (minimum) supply fuse should be used, and a
switch with a clear OFF marking having a contact
separation in both poles that provides full disconnection
under over-voltage category III conditions must be
incorporated into the fixed wiring in accordance with local
wiring regulations by a competent electrician. The dryer
should be positioned so that the disconnection switch
is clearly visible and easily accessible to the user. This
disconnection switch also provides the function of an
emergency stop control for the user.
■ A cord clamp bush is provided on the dryer, and should
be tightened on completion of wiring. The electrical mains
terminals are located behind the small rear access panel
(terminal block cover), and connections should be made
in accordance with the terminal markings. Remember to
replace the terminal access panel (terminal block cover).
NOTE: In accordance with the European EMC Directive
(2004/108/EC), the maximum electrical supply system
impedance to which the electric dryer should be connected
is declared to be 0.054 Ohm + j0.034 Ohm.
NOTE: Electrical safety standards: The manufacturer has
chosen compliance with IEC/EN.60335 standards as the most
appropriate for this product.
12
This is 3-wire appliance which must be earthed.
Do not earth to a gas pipe.
Failure to follow these instructions could result in
death, re, or serious injury.
2
If codes permit and an additional ground bond wire is used, it
is recommended that a qualified electrician determine that the
ground bond path is adequate.
Recommended Earthing Method
It is your responsibility to contact a qualified electrical installer
to ensure that the electrical installation is adequate and in
conformance with all local codes and ordinances.
Electric Shock Hazard