OPERATION OF CONTROLS
1. Press 'E' to turn ON / OFF the lamp
Normal Mode Operation
1. Press 'B' to turn ON at speed 1 / Adjust speed
2. Press 'C' to turn ON at low speed 3 / Adjust speed
3. Press 'D' to turn ON Turbo Speed / Turn OFF the appliance
Timer Mode Operation
1. Press 'A' once to turn OFF after 15 min
Press 'A' twice to turn OFF immediately
2.
MAINTENANCE
Switch off or unplug the appliance from the mains supply
before carrying out any maintenance work.
GREASE FILTER
* The grease filters should be cleaned frequently (every two months
of operation, or more frequently for heavy use). Use a warm
detergent solution.
* Grease filters are washable.
1. Remove the grease filter by pressing the latch on the filter (Fig5).
This will disengage the filter from the hood. Tilt the filter
downward and remove.
2. Wash the filters, taking care not to bend them. Allow them to be
11