Whirlpool GXW7330DXS0 Istruzioni per l'installazione e manuale d'uso e manutenzione - Pagina 8
Sfoglia online o scarica il pdf Istruzioni per l'installazione e manuale d'uso e manutenzione per Cappa di ventilazione Whirlpool GXW7330DXS0. Whirlpool GXW7330DXS0 28. 30" (76.2 cm) and 36" (91.4 cm) wall-mount canopy range hood
Anche per Whirlpool GXW7330DXS0: Manuale d'uso e manutenzione (28 pagine)
Install Range Hood
1. Using 2 or more people, hang range hood on 2 mounting
screws through the mounting slots on back of hood.
A
A. Mounting screws
B. Mounting slots
C. Lower mounting screws
2. Remove the grease filter. See "Range Hood Care" section.
3. Level the range hood and tighten upper mounting screws.
4. Install 2 - 5 x 45 mm lower mounting screws and tighten.
Connect Vent System
1. Install transition on top of hood (if removed for shipping) with
2 - 3.5 x 6.5 mm sheet metal screws.
A
B
A. Vent transition
B. 3.5 x 6.5 mm screw
2. Fit vent system over transition piece.
3. Seal connection with clamps.
4. Check that back draft dampers work properly.
8
B
1. Disconnect power.
2. Remove terminal box cover.
C
3. Remove the knockout in the terminal box and install a UL
4. Run home power supply wiring through ¹⁄₂" strain relief into
5. Use UL listed wire connectors and connect white wires (B)
Make Electrical Connection
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
listed or CSA approved ¹⁄₂" strain relief.
terminal box.
E
D
C
B
A
A. UL listed wire connectors
B. White wires
C. Black wires
D. Green (or bare) wire connected to
yellow-green wires
E. Home power supply
together.