Whirlpool KPEC992MSS Manuale d'uso e manutenzione - Pagina 2

Sfoglia online o scarica il pdf Manuale d'uso e manutenzione per Cappa di ventilazione Whirlpool KPEC992MSS. Whirlpool KPEC992MSS 10. 36/48" (91.4/121.9 cm) hood liner installation instructions

Whirlpool KPEC992MSS Manuale d'uso e manutenzione
Whirlpool
- ClC
8/16/04
2:25 PM
PAGE
1/21
RightFax
Your safety and the safety of
nthem is very important.
We haveprovidedmanyimportant
safety messages i n this manual and
onyourappliance. Always readand
obeyall safety messaoes.
Thisis thesafety alertsymbol
This symbol a lerts youto
potential hazards thatcankill
or hurtyou and others. A llsafety
messaoes willfollow the safety alert
symbol a ndeithertheword"DANGER"
or 'WARNING". T hese wordsmean:
Youcanbe killedor seriously Injured
it youdon't_
lollow
Instm_ione.
Youcanbe killedor seriously injured
if youdon'tfollow instructions.
Allsafetymessages willtell youwhat
the potential hazard is, LelJ y ou howto
reduce thechance of injury, a ndtell
youwhatcanhappenif the
instructions are notfollowed.
IMPORTANT: Observe all
governing codes and ordinances.
Proper installation is your
responsibility. Make sure you have
everything necessary for correct
installation. It is the responsibility of
the installer to comply with the
clearances specified.
Checkthe location where the hood
liner will be installed.The location
should be away from strong draft
areas, such as windows, doors, and
strong heating vents.
Mobile home installation
The installation of this hood liner
must conform to the Manufactured
Home Construction Safety
Standards, Title 24 CFR, Part 328
(formerly the Federal Standard for
Mobile Home Construction and
Safety, Title 24, HUD, Part 280) or
when such standard is not
applicable, the Standard for
Manufactured Home Installation
1982 (Manufactured Home Sites,
Communities and Setups) ANSI
A225.1/NFPA 501A*, or latest edition,
or with local codes.
WARNING --TO
REDUCE THE
RISK OF FIRE, ELECTRIC
SHOCK. OR INJURY TO
PERSONS, OBSERVE THE
FOLLOWING:
Installation work and electrical
wiring must be done by qualified
]ersan(s) in accordance with all
applicable Codes and Standards,
including Fire Rated
Construction. Sufficient air is
needed for proper combustion
and exhausting of gasesthrough
the flue (chimney) of fuel burning
equipment to prevent back
drafting. Follow the heating
equipment manufacturer's
guideline and safety standards
such as those published by the
National Fire Protection
Association (NFPA), and the
American Society of Heating
Refrigeration and Air
Conditioning Engineers
(ASHRAE), and the local code
authorities.
When cuttingor drillingintowall or
ceiling, do not damage electrical
wiringand other hiddenutilities.
Ducted fans mustalways be
vented to the outdoors.
WARNING -- To reducethe risk
of fire, use only metal ductwork.
This unitmust be grounded.
This hood liner mustbe usedwith
ExteriorBlowerModels:
KPEC992M rated for 900 cfm
(25.5 cm/m) or.
KPEU722M rated for 1200 cfm
(34.0 cm/m).
Both models are available from
your dealer.
This fan suitabable for use with
solid-state speed controls.
Tools and
materials needed
for installation:
• compassor 11"(27.9cm) circletemplate
• fiat bladescrewdriver
• Phillipsscrewdriver
• plTers
• metal snips
• drill
• 1-1/4"13.0cm) die. drill bit
• 5/16' (7.9cm)dis. drill bit
• pencil
• ruler
• sabersaw or keyholesaw
• ducttape
• 3/4" (10.0rnm}U.L- or C.SA.-Listed
strainrelief
IMPORTANT: Observe all
governing codes and ordinances.
The Exterior Blower is connected
to the fused electrical system at
the wiring box of the Hood Liner.
refer to the Installation
Instructions supplied with the
Exterior Blower model for the
electrical system.
It is the customer's responsibility:
•To contact a qualified electrical
installer.
•To assure that the electrical
installation is adequate and in
conformance with National
Electrical Code, ANSI/NFPA 70
-- latest edition*, or CSA
Standards C22.1-94, Canadian
Electrical Code, Part 1 and
C22.2 No.0-M91 - latest
edition** and all local codes
and ordinances.
A 120-volt, 60 hz, AC-only, fused
electrical system ia required. A
separate 15-amp circuit is
recommended.
A separate ground wire must be
used. It is recommended that a
qualified electrician determine
that the ground path is adequate..
Do not ground to a gas pipe.
Check with a qualified electrician if
you are not sure range hood is
properly grounded.
Do not have a fuse in the neutral
or ground circuit.
The connection at the hood liner
wiring box must be with copper
wire only.
IMPORTANT:
Save installation
Instructions
for
electrical inspector's use.
The 120-volt supply to the hood
liner wiring box should be
connected directly to the fused
disconnect (or circuit breaker) box
through flexible armored or
nonmetallic sheathed copper cable,
A U,L.- or C.S.A,-listad strain relief
must be provided at each end of the
power supply cable, Wire sizes
(COPPER WIRE ONLY) and
connections must conform with the
rating of the appliance as specified
on the model/serial
rating plate.
Wire sizes must conform to the
requirements of the National