Whirlpool RH2300 Series Manuale di istruzioni per l'installazione - Pagina 4

Sfoglia online o scarica il pdf Manuale di istruzioni per l'installazione per Cappa di ventilazione Whirlpool RH2300 Series. Whirlpool RH2300 Series 7. 24", 30" and 36" custom series range hood
Anche per Whirlpool RH2300 Series: Istruzioni per l'installazione e manuale d'uso e manutenzione (7 pagine), Istruzioni per l'installazione e manuale d'uso e manutenzione (7 pagine), Manuale di istruzioni per l'installazione (7 pagine)

Whirlpool RH2300 Series Manuale di istruzioni per l'installazione
centerline
centerline
6.
Determine and clearly mark a
vertical centerline on the wall and cabinet
in the area the vent opening will be made.
7-1/2"
centerline
7.
To wire through top, mark a line
7-1/2" from the right of the centerline on
the underside of the cabinet. Mark the
point on this line that is 2" from back wall.
Drill a 1-1/4" diameter hole through the
cabinet at this point. Note: If a cord-
connection kit is used, drill a 1-5/8"
diameter hole.
7-1/2"
65-1/4"
(to floor)
centerline
To wire through rear, mark a line 7-1/2" from
the right of the centerline on the wall. Mark
the point on this line that is 65-1/4" from the
floor (or 3/4" from underside of cabinet).
Drill a 1-1/4" diameter hole through wall at
this point.
Panel C
Numbers
correspond
to steps.
2"
from wall
(not cabinet
cabinet cutouts
frame)
8.
To make a 4" x 10-1/2" rectangle on the
underside of cabinet top and bottom:
a. Mark lines 1-1/2" and 5-1/2" from the
back wall on the centerline of the
underside of cabinet.
b. Mark lines 5-1/4" to the right and left of
the centerline on the underside of
cabinet.
c. Use saber and keyhole saws to cut a
rectangular opening for vent.
d. Repeat steps a-c for the underside of
3/4"
the top of the cabinet.
If venting through the wall with 3-1/4" x 10"
rectangular vent —
To make a 4" x 10-1/2" rectangle in the wall:
a. Measure from floor 65-7/8" and 62-3/8"
(or 1/8" and 3-5/8" down from underside
of cabinet) and mark on the centerline
on the back wall.
b. Mark lines 5-1/4" to the right and left of
the centerline on the underside of
cabinet.
c. Use saber and keyhole saws to cut a
rectangular opening for vent.
5. 12. 13.
*1-1/2"
*5-1/2"
5-1/4"
5-1/4"
* from wall, not
cabinet frame
10.
5. 12. 13.
*5-1/2"
5-1/4"
* from wall, not
cabinet frame
To transition from a 3-1/4" x 10" rectangular
vent to a 7" round vent and vent through
the roof —
Start by making a 4" x 10-1/2" rectangle on
the underside of cabinet bottom:
a. Mark lines 1-1/2" and 5-1/2" from the
back wall on the centerline of the
underside of cabinet.
b. Mark lines 5-1/4" to the right and left of
the centerline on the underside of
cabinet.
c. Use saber and keyhole saws to cut a
rectangular opening for vent.
7-5/8"
7-1/8"
R
*5"
*5-1/2"
cabinet
cutouts
Now make a 7-1/8" x 7-5/8" slot on the
underside of the cabinet tops.
d. Mark lines 5" and 5-1/2" from the back
wall on the centerline on the underside
of the top of cabinet.
e. Draw two 7-1/8" circles using the marks
made in step d as center points.
f. Use saber and keyhole saws to cut a
slotted (oval) opening to make installing
7" round vent easier.
3.
4. 14.
*1-1/2"
5-1/4"
*1-1/2"
* from
wall not
cabinet
frame