Whirlpool RH2330XJZ2 Istruzioni per l'installazione e manuale d'uso e manutenzione - Pagina 4

Sfoglia online o scarica il pdf Istruzioni per l'installazione e manuale d'uso e manutenzione per Cappa di ventilazione Whirlpool RH2330XJZ2. Whirlpool RH2330XJZ2 7. 24", 30", 36" custom series range hood
Anche per Whirlpool RH2330XJZ2: Elenco delle parti (1 pagine)

Whirlpool RH2330XJZ2 Istruzioni per l'installazione e manuale d'uso e manutenzione
'
I
E
'jI I
centerlJne
IIII Determine
and clearly mark a
vertical
centerline
on the wall and cabinet
in the area the vent opening
will be made,
Numbers
correspond
fo sfeps.
'1
'i I
i
i
i
i
i
!
i
i
centerlJne
2 It
from wall
(not cabinet
frame)
[]
To wire through
fop, mark a line
7-1/2" from the right of the centerline
on
the underside
of the cabinet,
Mark the
point on this line that is 2" from back wall,
Drill a 1-1/4" diameter
hole through
the
cabinet
at this point, Note: If a cord-
connection
kit is used, drill a 1-5/8"
diameter
hole,
I
I
'1,
'11
L
I
I
I
To wire through
rear, mark a line 7-1/2" from
the right of the cenferline
on the wall, Mark
the point on this line that is 65-1/4" from the
floor (or 3/4" from underside
of cabinet),
Drill a ] -1/4" diameter
hole through
wall at
this point,
cabinet cutouts
I
l
I
I I
To make a 4"x 10-1/2" rectangle
on the
underside
of cabinet
fop and bottom:
a. Mark lines 1-1/2" and 5-1/2" from the
back wall on the centerline
of the
underside
of cabinet,
b. Mark lines 5-1/4" to the right and left of
the centerline
on the underside
of
cabinet,
c. Use saber and keyhole
saws to cut a
rectangular
opening
for vent,
d. Repeat steps a-c for the underside
of
the top of the cabinet,
If venting
through
the wall with 3-1/4" x 10"
rectangular
vent --
To make a 4"x 10-1/2" rectangle
in the wall:
a. Measure from floor 65-7/8" and 62-3/8"
(or 1/8" and 3-5/8" down from underside
of cabinet)
and mark on the cenferline
on the back wall,
b. Mark lines 5-1/4" to the right and left of
the cenferline
on the underside
of
cabinet,
c. Use saber and keyhole
saws to cut a
rectangular
opening
for vent,
cabinet
5- '1/4"
* from wall, not
cabinet frame
To transition
from a 3-1/4" x 10" rectangular
vent to a 7" round vent and vent through
the roof --
Start by making
a 4"x 10-l/2"
rectangle
on
the underside
of cabinet
bottom:
a. Mark lines 1-1/2" and 5-1/2" from the
back wall on the cenferline
of the
underside
of cabinet,
b. Mark lines 5-1/4" to the right and left of
the cenferline
on the underside
of
cabinet,
c. Use saber and keyhole
saws to cut a
rectangular
opening
for vent,
7-1/8'L-_,_
7-5/8"
-'1-1/2"
*from
wall not
cabinet
frame
/
It
i
Now make a 7-1/8" x 7-5/8" slot on the
underside
of the cabinet
fops,
d. Mark lines 5" and 5-1/2" from the back
wall on the cenferline
on the underside
of the fop of cabinet,
e. Draw two 7-1/8" circles using the marks
made
in step d as center
points,
f.
Use saber and keyhole saws to cut a
slotted
(oval) opening
to make installing
7" round vent easier,
Panel C