INSTALLATION INSTRUCTIONS
NOTE: For vented installations, it is recommended
that the vent
system be installed before hood is installed.
Before making cutouts, make sure there is proper clearance
within the ceiling or wall for exhaust vent.
1. For vented installations, determine which venting method to
use: roof or wall.
2. Select a flat surface for assembling the range hood. Place
covering over that surface.
Excessive Weight Hazard
Use two or more people to move and install
range hood.
Failure to do so can result in back or other injury.
3. Using two or more people, lift the range hood onto covered
surface.
4. If cabinet has recessed bottom, add wood filler strips on each
side. Install screws to attach filler strips in locations shown.
Wood filler strips
(recessed cabinet
bottoms only)
J
71/2"
,
2" (5.1 cm)
(19 era)
i
from wall,
not cabinet
i
i
frame
i
Centerline
To wire through rear wall:
Mark a line 71/2 '' (19 cm) from the right of the centerline on the
wall. Mark the point on this line that is 651/4 '' (165.7 cm) from
the floor [or %" (1.9 cm) from underside of cabinet]. Drill a
11A'' (3 cm) diameter hole through wall at this point.
Style I - Cut Openings
for 31/4'' x 10" (8.3 cm x 25.4 cm)
Rectangular
Vent Sytem
Roof Venting
3"(7.5cm)
wall
To make a 4" x 101/2 '' (10.2 cm x 26.7 cm) rectangular cutout on
the underside of cabinet top and bottom:
Determine
Wiring Hole Location
Cut only one 11/4 '' (3.2 cm) diam. wiring access hole. See Step 2
for wiring hole location instructions.
Either wiring hole can be
used.
1. Determine and clearly mark a vertical centerline on the wall
and cabinet in the area the vent opening will be made.
i
i
_11
LI
A
2.
A. Centerline
To wire through
top:
Mark a line 7V2" (19 cm) from the right of the centerline on the
underside of the cabinet. Mark the point on this line that is
2" (5 cm) from back wall. Drill a 1W' (3 cm) diameter hole
through the cabinet at this point.
1.
2.
3.
4.
Mark lines 1V2" (3.8 cm) and 5_/2 '' (14 cm) from the back wall
on the centerline of the underside of cabinet.
Mark lines 51/4 '' (13.3 cm) to the right and left of the centerline
on the underside of cabinet.
Use saber or keyhole saw to cut a rectangular opening for
vent.
Repeat steps 1-3 for the underside of the top of the cabinet.
*From wall, not cabinet
frame