Whirlpool RH8300XLS SERIES Istruzioni per l'installazione - Pagina 2

Sfoglia online o scarica il pdf Istruzioni per l'installazione per Cappa di ventilazione Whirlpool RH8300XLS SERIES. Whirlpool RH8300XLS SERIES 5.

Whirlpool RH8300XLS SERIES Istruzioni per l'installazione
-.
TRAIN
CAP
II
I
1. Make atemplateortransfer
measurements
shown in Fig. 3
to cabinets
or wall.
2. Cut holes to accomodate
ventilating
duct allowing
W' (.6
cm) clearance
on all four sides for back vent. Allow %" (1.9
cm) clearance
toward front for vertical vent. Allow W' (.6 cm)
on other three sides for top vent.
3. Cut appropriate
hole for electrical
wiring.
4. Run wire through
wall or cabinets
according
to National
Electrical
Code and Applicable
local codes. (DO NOT turn
power on until installation
is complete.)
5. Remove blower housing
and filters for easier installation
See exhaust
unit assembly
illustration
on back page.
6. Remove screw holding
junction
box cover.
7. Remove proper electrical
knockout.
See Figure 3.
8. Remove proper venting
knockout.
See Figure 3. NOTE: If
horizontal
discharge
is selected
an additional
knockout
in
the blower cradle must be removed.
9. Attach
the damper
as shown
in Figure
5 for vertical
discharge
or Fig. 6 for horizontal
discharge.
10. Lift the hood into position. Mark location of four mounting
holes.
11. Remove
hood
and start all four screws
in center
of
narrow neck of keyhole
slot marked on cabinet
bottom.
12. Lift the hood into position
simultaneously
feeding
the
electrical
wire through
the knockout.
Follow applicable
local
codes and/or
latest National
Electrical
Code for electrical
conector
to be used at field wiring
entrance.
13. Tighten
screws to secure hood. Be sure screw head is in
narrow neck of keyhole
slot.
14. Install proper duct work. See page 4
15. Complete
electrical
wiring
in junction
box according
to
the National
Electrical
Code and applicable
Local Codes
NOTE:
This
unit
must
be
permanently
grounded
in
accordance
with the National
Electrical
Code and applicable
L,ocal codes.
16. Replace
junction
box cover.
17. Replace
blower.
Note
different
blower
positions
in
Figure
5 for vertical
venting
and Figure
6 for horizontal
venting.
See Page 3 for correct
blower
installation.
18. Replace
blower cover, light frame assembly
and filters.
NOTE: It has been found that a large part of the energy loss
of the average
home is due to outside
air infiltrating
the
structure.
Seal around
ductwork
where it passes through
outside
walls or ceiling.
Seal around electrical
wiring
also.
19. Be sure that damper which is supplied
with this model is
properly
installed.
(See Figures
1 & 2).
66"
IF
RAIN
CAP
HAS
A CAMPER,
REMOVE
DAMPER
BLADE
I
VERTICAL
VENTING
3:
x IO" RECTANGULAR
IF RAIN
CAP
riAS
A DAMPER.
REMOVE
DAMPER
BLAOE
FROM
HOOD.
66"
FIGURE 3
L
WIRING
6NOCKCUT