Whirlpool UXT5236AY Istruzioni per l'installazione e manuale d'uso e manutenzione - Pagina 10
Sfoglia online o scarica il pdf Istruzioni per l'installazione e manuale d'uso e manutenzione per Cappa di ventilazione Whirlpool UXT5236AY. Whirlpool UXT5236AY 32. 30" (76.2 cm) and 36" (91.4 cm) range hood
Anche per Whirlpool UXT5236AY: Istruzioni per l'installazione e manuale d'uso e manutenzione (36 pagine), Istruzioni per l'installazione e manuale d'uso e manutenzione (32 pagine), Istruzioni per l'installazione e manuale d'uso e manutenzione (34 pagine)
NOTE: The 7" (17.8 cm) round vent mounting plate and
3¹⁄₄" x 10" (8.3 x 25.4 cm) rectangular vent damper can be
installed up to 1" (2.5 cm) on either side of the hood
center to accommodate off-center ductwork.
A
E
B
A. Vertical vent connector with damper
B. 3.5 x 5 mm screws
C. Hinge pin
D. Vent knockouts
E. Horizontal vent connector with damper
If a vent damper is installed with a wall cap with damper,
check that they do not interfere with each other. Remove
the vent connector damper flap if they interfere.
Non-vented (recirculating) installations - No vent
attachments. Removal of the recirculation cover plate is
required. Remove the two screws from the recirculation
cover plate and remove.
A. Recirculation cover plate
B. Screws
10
B
C
D
C
A
B
Power Supply Cable Installation
1. For direct wire installations, run the home power supply cable
according to the National Electric Code or CSA standards
and local codes and ordinances. There must be enough
wiring from the fused disconnect (or circuit breaker) box to
make the connection in the hood electrical terminal box.
For optional power supply cord kit installations, follow the
instructions in the "Make Electrical Connection" section. See
the "Accessories" section for information on ordering.
NOTE: Do not reconnect power until the installation is
complete.
2. Remove the screw from the terminal box cover. Remove
terminal box cover and set aside.
A. Terminal box cover
B. Screw
3. Remove the power supply knockout from the top or rear of
the vent hood (depending on the incoming location of your
home power supply cable) and install a UL listed or CSA
approved ¹⁄₂" strain relief.
A
A. Power supply knockout
4. Using 2 or more people, lift the hood into final position. Feed
enough electrical wire through the ½" UL listed or CSA
approved strain relief to make connections in the terminal
box. Tighten the strain relief screws.
5. Position the range hood so that the large end of the keyhole
slots are over the mounting screws. Then push the hood
toward the wall so that the screws are in the neck of the slots.
Tighten the mounting screws, making sure the screws are in
the narrow neck of slots.
6. Connect ventwork to hood. Seal joints with vent clamps or
duct tape to make secure and airtight.
7. Check that back draft dampers work properly.
A
B