NOTE: It is recommended that the vent system be installed
before hood is installed.
Before making cutouts, make sure there is proper clearance
within the ceiling or wall for exhaust vent.
1. Disconnect power.
2. Depending on your model, determine which venting method
to use: roof, wall or non-vented (recirculating).
3. Select a flat surface for assembling the range hood. Place
covering over that surface.
4. Lift the range hood and set it upside down onto covered
surface.
5. If cabinet has recessed bottom, add wood filler strips on each
side. Install screws to attach filler strips in locations shown.
3" (7.6 cm)
3" (7.6 cm)
Wall
Determine Wiring Hole Location
Cut only one 1¹⁄₄" (3.2 cm) diameter wiring access hole. See
Step 2 for wiring hole location instructions.
1. Determine and clearly mark a vertical centerline on the wall
and cabinet in the area the vent opening will be made.
A. Centerline
INSTALLATION INSTRUCTIONS
Prepare Location
Wood filler strips
(recessed cabinet
bottoms only)
Cabinet
bottom
A
To wire through top:
1. Mark a line distance "A" from the right of the centerline on the
underside of the cabinet. Mark the point on this line that is
⁷⁄₈" (2.2 cm) from back wall. Drill a 1¼" (3.2 cm) diameter hole
through the cabinet at this point.
A. 8³⁄₈" (21.3 cm) for 30" (76.2 cm) models
11³⁄₈" (28.9 cm) for 36" (91.4 cm) models
To wire through wall:
1. Mark a line distance "A" from the right of the centerline on the
underside of the wall. Mark the point on this line that
is ⁷⁄₈" (2.2 cm) from the underside of the cabinet. Drill a
1¹⁄₄" (3.2 cm) diameter hole through the rear wall at this point.
A. 8³⁄₈" (21.3 cm) for 30" (76.2 cm) models
11³⁄₈" (28.9 cm) for 36" (91.4 cm) models
Style 1 - Cut Openings for 3¼" x 10" (8.3 cm x 25.4 cm)
Rectangular Vent System
Roof Venting
To make a 4¹⁄₄" x 10½" (10.8 cm x 26.7 cm) rectangular cutout
on the underside of cabinet top and bottom:
1. Mark lines ¹⁄₂" (1.3 cm) and 4³⁄₄" (12.1 cm) from the back wall
on the centerline of the underside of cabinet.
2. Mark lines 5¼" (13.3 cm) to the right and left of the centerline
on the underside of cabinet.
3. Use saber or keyhole saw to cut a rectangular opening for
vent.
⁷⁄₈" (2.2 cm)
A
from wall,
not cabinet
frame
Centerline
⁷⁄₈" (2.2 cm)
A
Centerline