Whirlpool W10240582A Istruzioni per l'installazione e manuale d'uso e manutenzione - Pagina 11

Sfoglia online o scarica il pdf Istruzioni per l'installazione e manuale d'uso e manutenzione per Cappa di ventilazione Whirlpool W10240582A. Whirlpool W10240582A 28. 30" (76.2 cm) and 36" (91.4 cm) range hood

Reinstall blower
For vented installation only:
IMPORTANT: To avoid damage, do not grasp blower by blower
wheels.
1. Position blower so that blower discharge lines up with
damper/vent connector.
Horizontal Vent
A
A. Blower discharge
2. Slip rods into mounting brackets on blower assembly.
B C
A. Blower
B. Mounting rod
C. Knurled nut
D. Blower wiring plug
3. Securely tighten knurled nuts.
4. Reconnect blower plug.
5. Reinstall bottom cover.
For non-vented (recirculating) installation only:
IMPORTANT: To avoid damage, do not grasp blower by blower
wheels.
1. Move mounting rods to front holes in hood support channels.
2. Position blower so that blower discharge lines up with
louvered opening on hood front.
A. Front holes
B. Blower discharge

Complete Installation

Vertical Vent
A
D
A
B
3. Slip rods into mounting brackets.
4. Securely tighten knurled nuts.
5. Reconnect blower plug.
6. Using a flat-blade screwdriver, pry louver cover off control
panel.
A
7. Reinstall bottom cover.
Install 2 x 75-watt (max.) or 1 x 75-watt and 1 x 25-watt
incandescent light bulbs.
1. Squeeze the plastic lens cover and remove it from the hood.
2. Screw light bulb into socket. If you are using a 25-watt light
bulb as a night light, screw into right-hand socket.
3. Repeat Step 2 for the other light bulb.
4. Replace lens cover by squeezing cover and inserting tabs
into slots.
Install filters
See "Metal Grease Filter" or "Non-vented (recirculating)
Installation Filters" in the "Range Hood Care" section.
B C
D
A. Blower
B. Mounting rod
C. Knurled nut
D. Blower wiring plug
A. Louver cover
A
A
11