Cleaning
IMPORTANT: Clean the hood and grease filters frequently
according to the following instructions. Replace grease filters
before operating hood.
Exterior Surfaces:
To avoid damage to the exterior surface, do not use steel wool
or soap-filled scouring pads.
Always wipe dry to avoid water marks.
Cleaning Method:
■
Liquid detergent soap and water, or all-purpose cleanser
■
Wipe with a damp soft cloth or nonabrasive sponge, and
then rinse with clean water and wipe dry.
Metal Grease Filter
1. Remove the filter by pulling the spring release handle,
and then pulling down the filter.
A
A. Spring release handle
2. Wash metal filters as needed in dishwasher or hot detergent
solution.
3. Reinstall the filter by making sure the spring release handle
is toward the left. Insert aluminum filter into upper track.
4. Push in spring release handle.
5. Push up on metal filter and release handle to latch into place.
Non-Vented (recirculating) Installation Filters:
The charcoal filter is not washable. It should last up to 6 months
with normal use. Replace with Charcoal Filter Kit Number
W10412939.
To replace charcoal filter:
1. Remove metal grease filter from range hood. See "Metal
Grease Filter" in this section.
2. Bend spring clips away from metal grease filter.
12
RANGE HOOD CARE
3. Place charcoal filter into top side of metal filter.
4. Bend spring clips back into place to secure the charcoal
5. Replace metal grease filter. See "Metal Grease Filter"
Replacing a Halogen Lamp
Turn off the range hood and allow the halogen lamp to cool.
To avoid damage or decreasing the life of the new lamp, do
not touch lamp with bare fingers. Replace lamp, using tissue
or wearing cotton gloves to handle lamp.
If new lights do not operate, make sure the lamps are inserted
correctly before calling service.
1. Disconnect power.
2. Use a flat-blade screwdriver and gently pry the light cover
3. Remove the lamp and replace with a 120-volt, 40-watt
4. Replace the light cover.
5. Reconnect power.
filter to the metal filter.
in this section.
loose.
maximum, halogen lamp made for a G-9 base.