General description

JSHD4 is a dual channel three-position enabling device, intended for use in hazardous areas where no other
protection is possible or practical. The device as a stand-alone unit is not sufficient for this task and must be
connected to a suitable control unit (safety relay or safety-PLC) with two channel inputs and short-circuit detection.
Also, the machinery or equipment causing the potential danger may need to be set in jog-mode or by other means
limited in movement, speed, temperature etc.
Two three-position push buttons operated by one common surface ensures a high level of safety, both when
released and when pressed into the third and final position. The safety contacts are closed only in the middle
position, but are opened if pressed further and remain open during the return to the top (resting) position.
The anti-tampering device consists of a capacitive sensor and an accelerometer. By combining these sensors the
device can be used to determine if an operator is holding the enabling device. This can be used if there is any risk
for tampering of the enabling device.
JSHD4 is based on a modular system that allows for a number of different versions of a complete enabling device
to be created, using different top parts (handles) and bottom parts (with different cables and connectors, AS-i
nodes, emergency stop, etc). There are also a number of accessories available, such as fittings for safety
switches/sensors, anti-tampering electronics, cables and resting stations. For more information, see chapter Model
overview.
For more details on JSHD4 operation, see chapter Operation.
Warning! The anti-tampering device is not a safety function; the safety relies on the three-position button being
operated as intended.

Safety regulations

Warning!
Carefully read through this entire manual before using the device.
The devices shall be installed by a trained electrician following the Safety regulations, standards and the Machine
directive.
Failure to comply with instructions, operation that is not in accordance with the use prescribed in these instructions,
improper installation or handling of the device can affect the safety of people and the plant.
For installation and prescribed use of the product, the special notes in the instructions must be carefully observed
and the technical standards relevant to the application must be considered.
In case of failure to comply with the instructions or standards, especially when tampering with and/or modifying the
product, any liability is excluded.