fireStorm SEQ36 Manuale d'uso - Pagina 6

Sfoglia online o scarica il pdf Manuale d'uso per Apparecchiature di registrazione fireStorm SEQ36. fireStorm SEQ36 14.

fireStorm SEQ36 Manuale d'uso

CLOCK MODE

Clock Mode sets the absolute time a Channel will fire, relative to a clock that starts when
the first Trigger Input is received.

Example 1

Channel 1 will fire 0.5 seconds after the Trigger Input is received.

Example 2

Channel 2 will fire 2.35 seconds after the Trigger Input is received.

Example 3

Channel 3 will fire 6 seconds after the Trigger Input is received.
Note: Channels do not have to fire in order. For example, Channel 2 could fire at 0m05:00
and Channel 1 could fire at 0m02:00.
Note: Channels that have identical times will fire together. For example, if Channel 1 and
Channel 4 are both set to 0m05:00 they will both fire 5 seconds after the Trigger Input is
received.
5 of 13