Clarion APX400.2M Manuale operativo e di installazione - Pagina 8
Sfoglia online o scarica il pdf Manuale operativo e di installazione per Amplificatore Clarion APX400.2M. Clarion APX400.2M 16. Two-channel amplifier
Mixed-Mode Satellite and Subwoofer System
FREQ (hz)
80
100
125
150
200
NOTE: Chart values based on 4 ohm speakers.
Figure 5 - The amplifier can be configured for a mixed-mode operation. The
table provides component values to create a 6dB per octave crossover at
specified frequencies. Use components that have a + 5% tolerance and
capacitors rated at 100V. NOTE: Choose the same frequency for both LP and
HP crossovers. Do not overlap frequencies, as this may damage the amplifier.
6
(Set INPUT SELECT Switch to STEREO)
L (mH)
C (uF)
8.0
497
6.4
398
5.1
318
4.2
265
3.2
199
Set X-Over Mode to OFF.