Acond Hydromodul PRO-R Manuale di installazione - Pagina 16
Sfoglia online o scarica il pdf Manuale di installazione per Scaldabagno Acond Hydromodul PRO-R. Acond Hydromodul PRO-R 17.
Be careful, hot water may flow out of the valve.
9.4 Disconnect from the mains
First, use the AcondTherm regulation to switch off the device and then disconnect the device
from the main by switching off the circuit breaker in the main home switchboard.
9.5 Cleaning
Clean the hydromodule with products designed for stainless materials.
Do not use any types of sprays around the hydromodulu. This is especially true
for
• Solvents
• Cleaning products containing chlorine
• Colors
• Glues
10 E-heater thermostat reset
The E-heater has a built-in safety thermostat that disconnects the heating rod from the power
supply if the heating water temperature is too high. If this happens, it is necessary to manually
reset the thermostat.
To reset the thermostat
1. Remove the Hydormodule covers, see chapter 7.5.
2. Diagnose if the thermostat is disconnected
a. In the AcondTherm regulation, manually start the heating rod by clicking on the
icon.
b. Check whether the contactor of the heating rod (marked KM1) displays contactor
(red color). If green is visible, the contactor has not switched on and the
thermostat needs to be reset.
3. Switch off the circuit breaker in the home main switchboard.
4. Reset the thermostat is done by pressing the button, see the following picture.
Installation manual
Hydromodul
15