ERROR MESSAGES
Low battery: If the vehicle has a battery voltage of less than 10.8 V, the boiler will stop. This is reset auto-
matically once the voltage reaches 11 V. If the voltage becomes lower, various error messages may also
occur. These are not genuine faults. Ensure that the boiler has the right voltage.
Fan restarts: Incorrect fan speed. New start attempt is made. Repeated faults results in Fan failure.If Fan
failure recurs after resetting, contact a dealer. If Fan restarts is displayed, no action is necessary.
Gas failure: The boiler has not managed to ignite the LPG flame. Ensure that gas is available.
Overheat red fail: Overheat protection (red cable) tripped. This fault can arise if the boiler is run at high
power at the same time as there are air pockets in the heating system, the heating system should then be
bled properly.
If the fault remains, contact a dealer.
Overheat blue fail: Overheat protection (blue cable) tripped.
Overheat PCB: The boiler's circuit board has overheat protection. If this gets too hot, the protection is
tripped. Allow the boiler to cool down before resetting.
* Window open: A window is open and the boiler stops running on gas. Gas operation of the boiler will
restart once the window is closed. Electrical operation continues to function.
Heater not found: There is a connection fault between the boiler and the control panel.
3rd party C. fail: Communication fault between Alde's panel and Alde Smart Control*.
Panel failure: Fault on the panel.
No match Heater/Panel: The circuit board in the boiler is not intended for the Alde Compact 3020 HE
and will not work with the 3020 HE panel.
Red connection fail: Problem with the red cable or red ports. There is no communication with the 3020
heater, AC or iNet.
Yellow connection fail: Problem with the cable between the Alde panel and the CI master panel or its ports.
iNet connection fail: Cannot find the INet box. Probably a problem with iNet. In the event
of "INet connection fail", this button is displayed. Pressing the button will remove the error.
Heater not found: Cannot find the 3020 heater. Most probably a problem with the heater's circuit board.
To reset some of the errors and restart, switch off the boiler from the panel, disconnect 230 V to the
vehicle and disconnect 12 V from the boiler.
10. RESETTING
Pressing Reset resets the panel to its factory settings. After resetting, the panel will be set as follows:
Boiler – Off mode; electrical operation – 1 kW; LPG heating – On mode; indoor temperature – 22°C. Other
functions are switched off.
NB. The functions that are checked under Installed functions (see section 11) will not be affected by a
reset. A reset will also cancel error messages in the error log.
Settings
Functions marked with a (*) are accessories, which are not installed on all vehicles, refer to the vehicle
12
manufacturer's instructions.