3Com REMOTE ACCESS SYSTEM 1500 Manuale di installazione - Pagina 4
Sfoglia online o scarica il pdf Manuale di installazione per Hardware di rete 3Com REMOTE ACCESS SYSTEM 1500. 3Com REMOTE ACCESS SYSTEM 1500 6. Superstack ii remote access system 1500
Anche per 3Com REMOTE ACCESS SYSTEM 1500: Nota di rilascio (12 pagine)
4
I/O M
I
ODULE
NSTALLATION
Removing an
I/O Module
Swapping I/O
Modules
G
S
S
II R
UIDE
UPER
TACK
Use the following steps to remove an I/O module:
CAUTION: The modules are not hot-swappable. Power off the unit
before installing, removing, or exchanging the modules. Failure to
do so could damage the modules.
1 Remove the AC power cord from the back of the RAS 1500 or RAS 1500
Expansion to power off the unit.
WARNING: Remove the telephone cables from the module before you
remove the module from the unit. Failure to do so could result in electric
shock.
2 Remove the telephone cables from the I/O module.
3 Loosen the two screws on the I/O module.
4 Place the screwdriver provided with the RAS 1500 in the small hole
beneath the I/O module's slot and push until the module ejects out of
place.
5 Remove the I/O module from the slot.
6 If you are not replacing the I/O module, you must install a blank face
plate.
Leaving the I/O slot open presents a potential safety hazard and the unit
may no longer meet FCC requirements.
If you swap a Basic Rate Interface (BRI) I/O module and analog I/O
module, reset the modem's settings. Otherwise, ports could hang. Two
examples are provided below. Be sure to provide the proper interface
(rm0, pem0, or pemX), slot (slot:1 or slot:2), and port numbers.
To reset an analog modem's configuration to the factory-default settings,
use the following CLI command:
set switched interface rm0/slot:1/mod:1 at_command AT&F0&W
To reset an ISDN modem's configuration to the factory-default settings,
use the following CLI commands:
set switched interface rm0/slot:1/mod:1 at_command AT&F0&W
set switched interface rm0/slot:1/mod:1 at_command ATZ!
A
S
1500
EMOTE
CCESS
YSTEM