Xerox DocuPrint 90 Manuale di pianificazione - Pagina 11
Sfoglia online o scarica il pdf Manuale di pianificazione per Stampante All in One Xerox DocuPrint 90. Xerox DocuPrint 90 22. Tape client job submission guide enterprise printing system
Anche per Xerox DocuPrint 90: Come iniziare (28 pagine), Manuale supplementare (48 pagine)
Xerox Document Binder 120-D (DB120-D)
Electrical Requirements
Device
Document Binder120-D
DocuPrint DocuTech 75/90
Bypass Transport
Environmental Requirements
Estimated Installation Time
The recommended location of the electrical wall outlet, mounted
on a rear wall is to be no more than 6 feet (1,829mm) away from
the rear center of the Document Binder 120-D.
North America
115 VAC, 60 Hz, 7A
Power cord: 6 - 8 ft (1,829 –
2,438 mm)
105 - 127 VAC 60 Hz, 2 A
Device
Document Binder120-D
Temperature
50 - 90° F (10 - 32°C)
Humidity
10 – 85% (non-condensing)
Heat Emission
108 btu / hr. (Energy Saver mode)
809 btu / hr. (Standby mode)
1106 btu / hr. (Operating mode)
Sound Emission
Standby: 46 dB
4 sheets binding: 68 dB
30 sheets binding: 66 dB
100 sheets binding: 66 dB
Altitude
0 – 13,000 ft. (0 – 4,000 m)
In North America, the CoverBind personnel install the DB120-D
and the estimated installation time is 2 hours. CoverBind
personnel also provides an initial 2 – 4 hour customer training.
In Europe, Bindomatic personnel install the DB120-D and the
estimated installation time is 2 hours. Bindomatic personnel also
provides an initial 2 – 4 hour customer training..
To contact Bindomatic and / or Coverbind, please go to:
Contact Information
1-5
Europe
220VAC, 50 Hz, 3.5A
Power cord: 6 - 8 ft (1,829 –
2,438 mm)
N/A