Anche per Xerox 850N - Phaser Color Solid Ink Printer: Specifiche tecniche (2 pagine), Manuale dell'operatore (16 pagine), Manuale supplementare (1 pagine), Manuale supplementare (11 pagine), Manuale di configurazione (1 pagine), Manuale di istruzioni per la pulizia (9 pagine), Manuale di aggiornamento (8 pagine), Manuale supplementare (26 pagine), Nota di rilascio (11 pagine), Nota di rilascio (11 pagine), Istruzioni per l'installazione (2 pagine)

Xerox 850N - Phaser Color Solid Ink Printer Nota di rilascio

9 Customer Issues Resolved

9.1 The following Customer issues were resolved
in 10.3.3. b 106
Issue Description
CGM default line width
9.2 The following Customer issues were resolved
in 10.3.3. b 106
Issue Description
CGM circle problem
CGM ellipse problem
IOT test print on 721 with
folder problem
9.3 The following Customer issues were resolved
in 10.3.2 b 201
Issue Description
Problem supporting 30" media
on 6030 / 6050 with 4.1
Page 26
Problem
The default line width was
calculated incorrectly and
resulted in the first drawing
element or fill to be too large
proportional to the size of the
drawing.
Problem
Some VERY small arcs with
large radii are printed as
complete circles.
Ellipses degenerating to a
single line and drawn through
180 degrees were
not rendered properly. This
appears as a "missing line"
problem.
When an IOT test print is
generated on a 721 with a
folder the Accxes controller
crashed due to an unexpected
message from the folder.
Problem
Interface change on the 6030
/ 6050 required a similar
change in FreeFlow Accxes
Resolution
The CGM interpreter now
properly calculates the default
line width.
Resolution
The CGM interpreter now
prints these as arcs and NOT
circles
The CGM interpreter now
detects this case and draws a
complete line.
The folder interface has been
corrected to deal with this
case properly.
Resolution
6030 / 6050 interface updated
to support new 30" selection