eControls Comfort365 C365T21 Manuale dell'installatore e dell'utente - Pagina 3

Sfoglia online o scarica il pdf Manuale dell'installatore e dell'utente per Termostato eControls Comfort365 C365T21. eControls Comfort365 C365T21 13.
Anche per eControls Comfort365 C365T21: Manuale dell'installatore e dell'utente (13 pagine), Manuale d'uso (4 pagine)

WIRING INSTRUCTIONS

!
Warning!
Turn the power to the HVAC equipment off before wiring.

WIRING DIAGRAM

Model R80CT-XX
Living Area Damper
GE HP
Y2
Y2
HVAC System
W2
E
G
G
Y
Y
W O or B
C
C
R
R
Model C365T21
Thermostat (in living area)
R
C
W/OB
Y1
G
W2E/Y2
TS
C365T21
Model TS5
Remote Temperature
Sensor for Sleeping Area
Model R80CT-XX
Sleeping Area
Damper
Model A80-MT
Damper Actuator
CLS
Modulating or
OPN
Open/Close
COM
24VAC,2.4VA
Made in USA
eControls, Inc.
Model A80-MT
Damper Actuator
CLS
Modulating or
OPN
Open/Close
COM
24VAC,2.4VA
Made in USA
eControls, Inc.
COM
CLS
OPN
COM
CLS
OPN
TS
Equipment Wiring, Gas/Electric, 2H/1C
Use 5-conductor, 18 or 20 gage, thermostat cable.
C365
Wire Color
Terminal
R
Red
C
Blue
W/OB
White
Y1
Yellow
G
Green
W2E/Y2
Brown
Equipment Wiring, Gas/Electric, 1H/2C
Use 5-conductor, 18 or 20 gage, thermostat cable.
C365
Wire Color
Terminal
R
Red
C
Blue
W/OB
White
Y1
Yellow
G
Green
W2E/Y2
Brown
Equipment Wiring, Heat Pump, 1 Compressor
Use 5-conductor, 18 or 20 gage, thermostat cable.
C365
Wire Color
Terminal
R
Red
C
Blue
WOB
White
Y1
Yellow
G
Green
W2E/Y2
Brown
Equipment Wiring, Heat Pump, 2-Compressor
Use 5-conductor, 18 or 20 gage, thermostat cable.
C365
Wire Color
Terminal
R
Red
C
Blue
WOB
White
Y1
Yellow
G
Green
W2E/Y2
Brown
Damper Wiring
Use 3-conductor, 18 or 20 gage, thermostat cable to wire from
the C365 Thermostat to the sleeping and living area dampers.
Ensure the damper in the sleeping area is wired to
the terminals labeled SLEEPING and damper in the
living area is wired to the terminals labeled LIVING.
C365
Wire Color
Terminal
COM
White
CLS
Red
OPN
Green
Multiple dampers can be used to construct the sleeping or
living zones. Daisy chain terminals– COM to COM, OPN to
OPN and CLS to CLS.
3
Equipment
Function
Terminal
R, Rc, Rh
24VAC Power
C
Common
W, W1
Stg1 Heating
Y, Y1
Cooling
G
Fan
W2
Stg2 Heating
Equipment
Function
Terminal
R, Rc, Rh
24VAC Power
C
Common
W, W1
Stg1 Heating
Y, Y1
Stg1 Cooling
G
Fan
Y2
Stg2 Cooling
Equipment
Function
Terminal
R, Rc, Rh
24VAC Power
C
Common
O or B
Rev Valve
Y, Y1
Compressor
G
Fan
W, W2 or E
Aux Heat
Equipment
Function
Terminal
R, Rc, Rh
24VAC Power
C
Common
O or B
Rev Valve
Y, Y1
Stg1 Compressor
G
Fan
Y2
Stg2 Compressor
Damper
Function
Terminal
COM
Common
CLS
Closes damper
OPN
Opens damper