CLARIUS LT Manuale d'uso - Pagina 2

Sfoglia online o scarica il pdf Manuale d'uso per Attrezzature per DJ CLARIUS LT. CLARIUS LT 2. Led illuminators

T rouble Shooting
Ensure all tests are undertaken by a qualified, trained engineer
and ensure safe working practices are followed at all times.
Step 1: Basics
Check power connection
Ensure power is 12-32V DC
Check the photocell is working - cover photocell, light
should turn on
Ensure power supply is suitable rated to product - check the
specifications
Step 2: Lamp Test
Check current draw of lamp corresponds to specification
Check current of lamp - see instructions for correct current
settings
To check lamp current remove +ve (red) lead from power
supply and connect a multimeter (set to 10A) in line with the
lamp. (One lead of multimeter in common (COM), other lead
into 10A socket of multimeter; set multimeter to read Amps).
Refer to PSU Specifications for correct current settings.
Step 3: Set up Camera, Lens and Illumination
Check alignment of lamp
Check camera lens - fully open at night and set correctly
Check model number to performance specification to
ensure required distance is achievable
Step 4: Call for further assistance
If the lamp is still not delivering the required performance,
please contact Technical Support for further assistance
Note down:
Model number and serial number of illuminator
Camera make and model
Lens make and model
Certifications
This product complies with the European Directive
89/336/EEC Electromagnetic Compatibility and 73/23/
EEC Low Voltage Directive by meeting the following
standards:
Safety:
EN60598-1:2008 Electrical Safety
EN60825-1:2007 LED/Laser Eye Safety
EMC:
EN61000-6-1:2007
EN61000-6-3:2007
EN61000-3-2:2006
EN61000-3-3:1995 AMD1 & AMD2
FCC:
FCC CFR Part15. 107 and 15.109
IP:
IP67 in accordance with EN 60529:1992
AMD1 7643,1993 AMD2 10931,2000
WEEE:
Waste Electrical & Electronic Equipment
European directive 202/96/EC
RoHS:
Restriction of Hazardous Substances
European directive 202/95/EC
This symbol on the product means that the electrical and/or
electronic equipment to which it relates should be disposed of
at the end of life separately from domestic household waste.
There are separate collection systems for recycling in the EU. For
more information please contact the Local Authority or supplier
of the product.
ACCESSORIES
SMB1
'L' Wall mount bracket for single illuminator
Compatible with all Clarius infrared & white light
illuminators
Allows up to 180 degrees rotation
Fully adjustable (left,right, up & down)
DMB1
Dual illuminator mounting bracket compatible with all
Clarius infrared & white light illuminators
Doubles the angle of illumination
Increases illumination distance by a factor of 1.4x
when using two equivalent illuminators
TMB1
Triple illuminator mounting bracket compatible with
all Clarius infrared & white light illuminators
Triples the angle of illumination
Increases the illumination distance by a factor of 1.7x
when using three equivalent illuminators
PMB1
Pole mounting bracket compatible with all Clarius
infrared & white light illuminators including SMB1.
DMB1 and TMB1
Supplied with straps to fit 7.5 to 20cm diameter pole
Recommended PSU1
Model: ALT-30-24
Output: 24V DC / 1.25A Max
Input: 100-250 V AC / 0.45A 50/60Hz
Ratings: IP67
Dimensions: 200 x 20 x 29mm