INSTALL DAMPERS
Install an R80CT damper in the duct supplying air to the
sleeping space and wire the terminals to the corresponding
terminals on the C365T11. Install a second R80CT damper in
the duct supplying air to the living space and wire it to the
C365T11. Each damper uses 2.4VA of power.
Ensure that damper installation does not cause
!
obstruction to the damper blade.
When two or more dampers are required to define the sleeping
or living space, the damper may be wired in parallel. LEDs on
the damper actuator indicate when the damper is fully open
(green) or fully closed (red). When properly installed, the
dampers will never fully close.
DAMPER WIRING
!
Warning!
Turn the power to the HVAC equipment off before wiring.
Use 3-conductor, 18 or 20 gage, thermostat cable to wire from
the C365T11 Thermostat to the sleeping and living space
dampers. There are separate terminals for the sleeping and
living space dampers.
Ensure the damper for the sleeping space is wired to
the terminals labeled SLEEPING and the damper for
the living space is wired to the terminals labeled
LIVING.
C365
Wire Color
Terminal
COM
White
CLS
Red
OPN
Green
Multiple dampers can be used to construct the sleeping or living
spaces. Daisy chain terminals– COM to COM, OPN to OPN
and CLS to CLS.
INSTALLER SECTION
Green LED
Red LED
Damper
Function
Terminal
COM
Common
CLS
Closes Damper
OPN
Opens Damper
WIRING
!
Warning!
Turn the power to the HVAC equipment off before wiring.
Gas/Electric, 1H/1C
Use 5-conductor, 18 or 20 gage, thermostat cable.
C365
Wire Color
Terminal
R
C
W
Y
G
NC

TEMPERATURE SENSOR WIRING

!
Warning!
Turn the power to the HVAC equipment off before wiring.
Use 2-conductor, 18 or 20 gage, thermostat cable to wire from
the C365T11 Thermostat to the temperature sensor in the
sleeping space.
Single Sensor Installation
Use one (1) Model TS510W sensor.
Dual Sensor Installation
Use two (2) Model TS520W sensors.
C365
Wire Color
Terminal
TS
TS
H A N
T I G
Page 3 of 16
Equipment
Terminal
Red
R, Rc, Rh
Blue
C
White
W, W1
Yellow
Y, Y1
Green
G
NO CONNECTION TO THIS TERMINAL
Sensor
Terminal
White
SNR
Red
SNR
Printed circuit board
Brass washer
D
H T E
N
Place wire between brass washer
and the printed circuit board and
hand tighten screw.
The TS5 sensor can be installed
in a single gang box or directly
to the wall using the hardware
provided.
Function
24VAC Power
Common
Heating
Cooling
Fan
Function
Thermistor
Thermistor