• Portamento time is fixed to 0 when the PORTAMENTO CONTROL is
used.
• HARMONIC CONTENT applies adjustment to the resonance value that
is set by the voice. This parameter specifies relative change with the
value of 64 producing 0 adjustment. As values get higher the sound
becomes increasingly eccentric. Note that for some voices the effective
parameter range is narrower than the legal parameter range.
• RELEASE TIME applies adjustment to the envelope release time set by
the voice. This parameter specifies relative change with the value of 64
producing 0 adjustment.
• ATTACK TIME applies adjustment to the envelope attack time set by the
voice. This parameter specifies relative change with the value of 64
producing 0 adjustment.
• BRIGHTNESS applies adjustment to the cut-off frequency set by the
voice. This parameter specifies relative change with the value of 64
producing 0 adjustment. Lower voices produce a softer sound. For some
voices the effective parameter range is narrower than the legal
parameter range.
(3-2) CHANNEL MODE MESSAGES
STATUS
1011nnnn(BnH) n = 0 - 15 VOICE CHANNEL NUMBER
CONTROL NUMBER
0ccccccc
CONTROL VALUE
0vvvvvvv
(3-2-1) ALL SOUND OFF (Receive only)
(CONTROL NUMBER = 78H , DATA VALUE = 0)
Switches off all sound from the channel. Reset Note On and Hold On conditions established
by Channel Messages.
(3-2-2) RESET ALL CONTROLLERS (Receive only)
(CONTROL NUMBER = 79H , DATA VALUE = 0)
Resets controllers as follows.
PITCH BEND CHANGE
0 (Center)
AFTER TOUCH
0 (min.)
MODULATION
0 (min.)
EXPRESSION
127 (max.)
SUSTAIN
0 (off)
SOSTENUTO
0 (off)
SOFT PEDAL
0 (off)
Sets number to null. (Internal data remains unchanged)
NRPN
Sets number to null. (Internal data remains unchanged)
RPN
Resets portamento source note number
PORTAMENT CONTROL
PORTAMENTO
0 (off)
(3-2-3) LOCAL CONTROL (Receive only)
(CONTROL NUMBER = 7AH , DATA VALUE = 0/7FH)
When the DATA VALUE = 7FH, LOCAL ON is activated where playing the keys on the
keyboard will produce sound.
When the DATA VALUE = 0, LOCAL OFF is activated where playing the keys on the
keyboard will not produce any sound.
(3-2-4) ALL NOTES OFF (Receive only)
(CONTROL NUMBER = 7BH , DATA VALUE = 0)
Switches off all of the channel's "on" notes. However, any notes being held by SUSTAIN or
SOSTENUTO continue to sound until SUSTAIN/SOSTENUTO goes off.
(3-2-5) OMNI OFF (Receive only) (CONTROL NUMBER = 7CH , DATA VALUE = 0)
Same processing as for All Notes Off.
(3-2-6) OMNI ON (Receive only) (CONTROL NUMBER = 7DH , DATA VALUE = 0)
Same processing as for All Notes Off. Omni On is not executed.
(3-2-7) MONO (Receive only) (CONTROL NUMBER = 7EH , DATA VALUE = 0)
Same processing as for All Notes Off. If the 3rd byte is in a range of 0-16 the corresponding
channel will be changed to Mode 4 (m=1).
(3-2-8) POLY (Receive only) (CONTROL NUMBER = 7FH , DATA VALUE = 0)
Same processing as for All Sounds Off and the corresponding channel will be changed to
Mode 3.
c = CONTROL NUMBER
v = DATA VALUE
(3-3) REGISTERED PARAMETER NUMBER(RPN)
STATUS
1011nnnn(BnH) n = 0 - 15 VOICE CHANNEL NUMBER
RPN LSB
01100100(64H)
RPN LSB NUMBER
0ppppppp
RPN MSB
01100101(65H)
RPN MSB NUMBER
0qqqqqqq
DATA ENTRY MSB
00000110(06H)
DATA VALUE
0mmmmmmm
DATA ENTRY LSB
00100110(26H)
DATA VALUE
0lllllll
First appoints the parameter for RPN MSB/LSB, then sets the parameter value for data entry
MSB/LSB.
RPN
D.ENTRY
LSB MSB
MSB LSB PARAMETER NAME
00H 00H
mmH —
PITCH BEND SENSITIVITY
01H 00H
mmH llH FINE TUNE
02H 00H
mmH —
COARSE TUNE
7FH 7FH
NULL
(3-4) NON-REGISTERED PARAMETER NUMBER(NRPN) (Receive only)
STATUS
1011nnnn(BnH) n = 0 - 15 VOICE CHANNEL NUMBER
NRPN LSB
01100010(62H)
NRPN LSB NUMBER
0ppppppp
NRPN MSB
01100011(63H)
NRPN MSB NUMBER
0qqqqqqq
DATA ENTRY MSB
00000110(06H)
DATA VALUE
0mmmmmmm
First appoints the parameter for NRPN MSB/LSB, then sets the parameter value for data entry
MSB/LSB.
NRPN
D.ENTRY
MSB LSB MSB LSB PARAMETER NAME DATA RANGE
01H 08H mmH —
VIBRATO RATE
01H 09H mmH —
VIBRATO DEPTH
01H 0AH mmH —
VIBRATO DELAY
01H 20H mmH —
FILTER CUTOFF FREQUENCY 00H - 40H - 7FH (-64 - 0 - +63)
01H 21H mmH —
FILTER RESONANCE
01H 63H
mmH —
EG ATTACK TIME
01H 64H mmH —
EG DECAY TIME
01H 66H mmH —
EG RELEASE
14H rrH mmH —
DRUM FILTER CUTOFF FREQ. 00H - 40H - 7FH (-64 - 0 - +63)
15H rrH mmH —
DRUM FILTER RESONANCE
16H rrH mmH —
DRUM AEG ATTACK RATE 00H - 40H - 7FH (-64 - 0 - +63)
17H rrH mmH —
DRUM AEG DECAY RATE
18H rrH mmH —
DRUM PITCH COARSE
19H rrH mmH —
DRUM PITCH FINE
1AH rrH mmH —
DRUM LEVEL
1CH rrH mmH —
DRUM PANPOT
1DH rrH mmH —
DRUM REVERB SEND LEVEL 00H - 7FH (0 - max.)
1EH rrH mmH —
DRUM CHORUS SEND LEVEL 00H - 7FH (0 - max.)
1FH rrH mmH —
DRUM VARIATION SEND LEVEL 00H - 7FH (0 - max.)
The MSB 14H-1FH (for drums) message is received when multi-part parameters PART
MODE = DRUMS1...2.
rrH : drum instrument note number
(3-5) SYSTEM REALTIME MESSAGES
(3-5-1) MIDI CLOCK
STATUS
11111000 (F8H)
Transmission: 96 clocks per measure are transmitted.
Reception: If the instrument's clock is set to external, after FAH is received from the external
device the instrument's clock will sync with the 96 beats per measure received from the external
device.
Decides whether the internal clock, or Timing Clocks received via the MIDI IN will be used.
(3-5-2) START
STATUS
11111010 (FAH)
Transmission: Transmitted when instrument's Rhythm or Song playback is started.
Reception: Depending upon the condition, Rhythm, Song Playback, or Song Rec will start.
(3-5-3) STOP
STATUS
11111100 (FCH)
Transmission: Transmitted when instrument's Rhythm or Song playback is stopped.
Reception: Depending upon the condition, Rhythm, Song Playback, or Song Rec will stop.
p = RPN LSB (refer to the list below)
q = RPN MSB (refer to the list below)
m = Data Value
l = Data Value
DATA RANGE
00H-18H (0 - 24 semitones)
{mmH,llH} = {00H,00H}-{40H,00H}-{7FH,7FH}
(-8192*100/8192) - 0 - (+8192*100/8192)
28H - 40H - 58H (-24 - 0 - +24 semitones)
Clears the current RPN number setting.
Does not change the internal parameter settings.
p = NRPN LSB (refer to the list below)
q = NRPN MSB (refer to the list below)
m = Data Value
00H - 40H - 7FH (-64 - 0 - +63)
00H - 40H - 7FH (-64 - 0 - +63)
00H - 40H - 7FH (-64 - 0 - +63)
00H - 40H - 7FH (-64 - 0 - +63)
00H - 40H - 7FH (-64 - 0 - +63)
00H - 40H - 7FH (-64 - 0 - +63)
00H - 40H - 7FH (-64 - 0 - +63)
00H - 40H - 7FH (-64 - 0 - +63)
00H - 40H - 7FH (-64 - 0 - +63)
00H - 40H - 7FH (-64 - 0 - +63)
00H - 40H - 7FH (-64 - 0 - +63)
00H - 7FH (0 - max.)
00H
,01H - 40H
- 7FH
(random,left - center - right)
CVP-202
15