Network Connection Example

If you connect the TXn units' [NETWORK] connector to a computer via an Ethernet cable, you'll be able to mon-
itor/control the TXn units from Amp Editor. Including computers and other equipment, a total of up to 253 units
can be connected in a single network.
Amp Editor
IP Address: 192.168.0.253
Ethernet
cable
Network switch
• If you wish to connect multiple TXn units, use a network switch that supports 100Base-TX/10Base-T.
NOTE
• The Ethernet cable between the network switch and the TXn can be up to 100 meters long. Due to the quality of cables and net-
work switch performance, however, proper operation at the maximum length cannot be guaranteed in some cases.
• Since the TXn supports Auto MDI/MDI-X, it will automatically detect whether the connected cable is of the straight type or
crossover type, and will configure itself to create the optimal connection. Therefore, you can use either a straight or crossover
cable.
• To prevent electromagnetic interference, use an STP (Shielded Twisted Pair) cable.
• Refer to the Amp Editor Installation Guide and the Amp Editor Owner's Manual for information on the TXn initial setup for using
the TXn in a network.
14
TX6n/5n/4n Owner's Manual
Ethernet
cable
Device ID: 1
IP Address: 192.168.0.1
Device ID: 2
IP Address: 192.168.0.2
Device ID: 3
IP Address: 192.168.0.3
Device ID: 4
IP Address: 192.168.0.4
Device ID: 5
IP Address: 192.168.0.5