Clark-Reliance Jacoby Tarbox Phaeton SL Series Istruzioni per l'installazione, il funzionamento e la manutenzione - Pagina 2
Sfoglia online o scarica il pdf Istruzioni per l'installazione, il funzionamento e la manutenzione per Apparecchiature di illuminazione Clark-Reliance Jacoby Tarbox Phaeton SL Series. Clark-Reliance Jacoby Tarbox Phaeton SL Series 4. Sight light
®
Phaeton
SL/HL Sight Light
To place the Phaeton SL/HL into Service:
1. Place the light directly onto the desired window.
2. Mount light to sight flow indicator or sight window with supplied mounting hardware.
3. Remove the plug in the ¾" NPT conduit connection. Open the housing. The Power Supply has a
2-position terminal block, ready to connect to the customer's power. All electrical specifications
must comply with NEC guidelines. After connecting the power, close the housing.
4. IMPORTANT: The customer must have a conduit sealing fitting within 18" of the Power
Supply.
CAUTION: Verify that the area is free of flammables before continuing.
5. Turn the power on, then connect the light to the power supply using the supplied DC power cord.
The Phaeton SL should be lit.
Warning: To avoid possible damage to eyes, do not look directly into the Phaeton sl light
ring.
If the cable will not reach the Power Supply, contact your local representative for the required DC
extension cord. Do not attempt to cut and splice the cord.
6. If the Phaeton SL is not lit, check the connections between the Light and the Power Supply and
check the power source. If Light remains unlit, turn the power source off and disconnect the unit
from the power source. IMPORTANT: Take the Power Supply and Light to a non-hazardous
environment. DO NOT REMOVE THE COVER IN A HAZARDOUS LOCATION WHEN POWER
IS ON.
7. Remove the Power Supply cover and connect the Power Supply to a power source in the
workshop. An LED will be lit if it is wired correctly. If the LED is not lit, check the (3) fuses and
replace as needed. If the LED remains unlit, call the factory for more support. Once the LED is lit,
replace the cover on the Power Supply and install the equipment in its working positions as
described in the previous procedures.
NOTE: See Drawing CI-26677 for safety information for hazardous locations.
Associate Equipment [Exia]
16633 Foltz Parkway ● Strongsville, OH 44149 USA ● Telephone: +1 (440) 572-1500
www.Jerguson.com ● [email protected]
IOM T500.7
2021.05
2